2.1.3

 

Terminals and Interfaces of Type II and Type III 6-Series Indoor 

Station 

Figure 2-3

 

Terminals of Type II and Type III 6-Series Indoor Station 

Table 2-3

 

Terminals Description 

Name 

No. 

Interface 

Description 

Terminals 

A1 

AIN1 

Zone Detector Input Terminal 1 

A2 

AIN2 

Zone Detector Input Terminal 2

 

A3 

GND 

Grounding   

2.2

 

Wiring Description 

2.2.1

 

Wiring of 8-Series Indoor Station 

There are 20 pins in the terminal on the rear panel of the indoor station: 4 RS-485 pins, 

4 GND pins, 4 alarm output pins, and 8 alarm input pins.   

To access the alarm input device, refer to Figure 2-4. 

To access the alarm output device, refer to Figure 2-5.   

 

Figure 2-4

 

Wiring Description (Alarm Input Device) 

Содержание HYU-559

Страница 1: ...VIDEO INTERCOM INDOOR STATION HYU 559 Quick Start Guide ...

Страница 2: ...ERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW OUR COMPANY SHALL N...

Страница 3: ...cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014 30 EU the RoHS Directive 2011 65 EU 2012 19 EU WEEE d...

Страница 4: ...ll or dismantle the device z When the product is installed on wall or ceiling the device shall be firmly fixed z If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center z If the product does not work properly please contact your dealer or the nearest service center Never attempt to disassemble the device yourself...

Страница 5: ...use the acidic sweat of the fingers may erode the surface coating of the device cover z Please use a soft and dry cloth when clean inside and outside surfaces of the device cover do not use alkaline detergents z Please keep all wrappers after unpack them for future use In case of any failure occurred you need to return the device to the factory with the original wrapper Transportation without the ...

Страница 6: ...erfaces of Type II and Type III 6 Series Indoor Station 7 2 2 Wiring Description 7 2 2 1 Wiring of 8 Series Indoor Station 7 2 2 2 Wiring of Type I 6 Series Indoor Station 8 2 2 3 Wiring of Type II and Type III 6 Series Indoor Station 9 3 Installation 10 3 1 Installation Accessory Description 10 3 2 Wall Mounting with Junction Box 10 4 Getting Started 12 4 1 Activate Indoor Station 12 4 2 Set SIP ...

Страница 7: ... Management Center Touch Key 9 LCD Display Screen 10 Microphone Figure 1 2 Rear Panel Table 1 2 Components Description No Description 11 TF Card Slot 12 Serial Port 13 Mechanical Switch 14 Power Supply Indicator 15 Network Interface 16 Loudspeaker z Hold the SOS touch key to trigger a SOS alarm and upload the alarm message to the management center the client software or the master station z The Un...

Страница 8: ... 7 Management Center Key 8 LCD Display Screen 9 Microphone Figure 1 4 Rear Panel Table 1 4 Components Description No Description 10 Power Supply Interface 11 Network Interface 12 Terminals 13 Loudspeaker z Hold the SOS touch key to trigger a SOS alarm and upload the alarm message to the management center the client software or the master station z The Unlock key is valid only when does the indoor ...

Страница 9: ...9 Microphone Figure 1 6 Rear Panel Table 1 6 Components Description No Description 10 Power Supply 11 Network Interface 12 Terminals 13 Loudspeaker z Hold the SOS touch key to trigger a SOS alarm and upload the alarm message to the management center the client software or the master station z The Unlock key is valid only when does the indoor station speak with the door station or open the live vie...

Страница 10: ...Video Intercom Indoor Station Quick Start Guide 4 Keys Hold Press SOS Key Return Key Direction KeysŸandŻ Unlock Key Live View Key Alarm Direction KeysźandŹ Management Center Key Confirm Key ...

Страница 11: ...485 Communication Port A1 RS485B RS 485 Communication Interfaces A2 RS485B A3 RS485A A4 RS485A Grounding A5 GND Grounding A6 GND Grounding ALARM OUT Alarm Output A7 COM1 Alarm Relay Output Terminal 1 Dry Contact A8 NO1 A9 COM2 Alarm Relay Output Terminal 2 Dry Contact A10 NO2 ALARM IN Zone Input B1 JIN8 Zone Detector Input Terminal 8 B2 JIN7 Zone Detector Input Terminal 7 B3 JIN6 Zone Detector Inp...

Страница 12: ...Type I 6 Series Indoor Station Table 2 2 Descriptions of Terminals and Interfaces Name No Interface Description Terminals A1 RS485 RS 485 Communication Interfaces A2 RS485 A3 AIN1 Zone Detector Input Terminal 1 A4 AIN2 Zone Detector Input Terminal 2 A5 AIN3 Zone Detector Input Terminal 3 A6 AIN4 Zone Detector Input Terminal 4 B1 AIN5 Zone Detector Input Terminal 5 B2 AIN6 Zone Detector Input Termi...

Страница 13: ...rminals A1 AIN1 Zone Detector Input Terminal 1 A2 AIN2 Zone Detector Input Terminal 2 A3 GND Grounding 2 2 Wiring Description 2 2 1 Wiring of 8 Series Indoor Station There are 20 pins in the terminal on the rear panel of the indoor station 4 RS 485 pins 4 GND pins 4 alarm output pins and 8 alarm input pins To access the alarm input device refer to Figure 2 4 To access the alarm output device refer...

Страница 14: ... I 6 Series Indoor Station There are 12 pins in the terminal on the rear panel of the indoor station 2 RS 485 pins 1 GND pin 1 alarm output pin and 8 alarm input pins To access the alarm input device refer to Figure 2 6 To access the alarm output device refer to Figure 2 7 Figure 2 6 Wiring Description Alarm Input Device ...

Страница 15: ...tput Device 2 2 3 Wiring of Type II and Type III 6 Series Indoor Station There are 3 available pins in the terminal on the rear panel of the indoor station 2 alarm input pins and 1 GND pin To access the alarm input device refer to Figure 2 8 Figure 2 8 Wiring Description Alarm Input Device ...

Страница 16: ...re 3 1 Wall Mounting Plate 3 2 Wall Mounting with Junction Box Wall mounting installations are the same for the 6 series indoor stations and the 8 series indoor stations Here we take the wall mounting of 6 series indoor station as an example Before you start z Make sure the device in the package is in good condition and all the assembly parts are included z The power supply the indoor station supp...

Страница 17: ...l 3 Fix the wall mounting plate to the junction box with 2 screws Screws Wall Mounting Plate Junction Box Figure 3 2 Install the Plate 4 Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots on the rear panel of the indoor station during which the lock catch will be locked automatically Hooks Slot Slot Lock Catch Figure 3 3 Hook the Indoor Station t...

Страница 18: ...eft the Live View key works as direction keys źandŹ to turn down and right and the Management Center key works as a confirm key 4 1 Activate Indoor Station You can configure and operate the indoor station only when you activate it You must create a password to activate the indoor station for your first time usage and when it is not activated Steps 1 Power on the device to enter the activation inte...

Страница 19: ...tation and the management center master station in the same video intercom system 2 types of SIP protocol are available for the indoor station Private Protocol and Standard Protocol z Rebooting the indoor station is required when you switch the SIP protocol between the private SIP protocol and the standard SIP protocol z All linked device IP should be configured again after you change the SIP prot...

Страница 20: ... management page Figure 4 3 Device Management 4 Tap SIP Sever and enter the IP address of the SIP server 5 Tap to save the SIP server added 4 2 2 Set Standard SIP With the standard SIP your indoor station can connect to any intercom device software client and phones which also support the standard SIP Before you Start ...

Страница 21: ...9 zThe default SIP protocol is private protocol zRebooting the indoor station is required when you change to Standard Protocol from Private Protocol Figure 4 4 SIP Protocol Selection 3 Set VoIP account z The account you entered here must be the same with the account you added in the standard SIP server z The phone number should be a numeric which is up to 16 digits And the phone number will be the...

Страница 22: ...ters after activating the indoor station What s more the indoor station can work normally in an intercom system only when its IP address is in the same network segment with other devices in the same system The indoor station s default IP address is 192 0 0 64 Two ways are available for you to set indoor station s IP address DHCP and set IP address manually Steps 1 Tap Settings Configuration Networ...

Страница 23: ...IP address subnet mask and network gateway 3 Tap OK 4 3 2 Set Linked Device IP Linked network parameters refers to the network parameters of devices like door station doorphone master station center etc to which the indoor station is linked Linked devices for the indoor station refers to door station center master station and doorphone With the private SIP protocol intercom can be realized only wh...

Страница 24: ... adding with the standard SIP protocol z Here take door station network settings as example Steps 1 Tap Settings Configuration Device to go to the device management page Default admin password is 888999 Figure 4 8 Device Management Private SIP Figure 4 9 Device Management Standard SIP ...

Страница 25: ...o call the indoor station and the indoor extension in an intercom system The indoor station No is composed of the floor No and the room No For example the indoor station No 401 refers to the room 1 on the fourth floor and the indoor station No 512 refers to the room 12 on fifth floor and the indoor station 2302 refers to the room 2 on the 23rd floor The indoor extension No Should be a numeric from...

Страница 26: ...tation No Room No and the floor No For Example When set the Room No as 2 and the Floor No as 2 then the indoor station No is 202 Figure 4 12 Set Indoor Station No 3 Select Indoor Extension to set the indoor extension No and the room name For Example Set the indoor extension No as 1 and the room name as Hello Room What to do next ...

Страница 27: ...Video Intercom Indoor Station Quick Start Guide 21 You can press 201 on the door station to call the indoor station and press 1 on the indoor station to call indoor extension ...

Страница 28: ... distance between two devices is recommended to be more than 10 meters Here the devices refer to indoor station outdoor station and master station 5 2 Wiring Cables Cable Specification Power Cord of Door Station RVV 2 1 0 Network Cable of Door Station UTP five Categories Door Lock Wiring With Door Magnetic RVV 4 1 0 Door Lock Wiring Without Door Magnetic RVV 2 1 0 Exit Button Wiring RVV 2 0 5 Exte...

Страница 29: ...www hyundai security tech Licensed by HYUNDAI Corporation Korea ...

Отзывы: