S01
S02
S03
S04
S05
S07
S08
S09
S12
S13
S14
S10
S11
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30
S31
S32
S15
S16
S06
10.0
10.0
60.00
60.00
5.0
10.0
0
0
0
0
0
0
0
100.0
1
0
4
-
-
-
-
-
-
-
-
-
-
-
0.1
0.001
0.001
0.1
0.01
0.1
0.001
0.001
0.1
0.01
0.1
100.0
30.00
20.00
999.9
100.0
100.0
30.00
20.00
999.9
100.0
100.0
0
0.00
0.00
10.0
10.0
0
60.00
0.1
0.1
0.00
S 04
0.0
0.0
0
20.0
0
0
2
0
0.00
0.00
0.1
0.1
0
0.00
3000
3000
S 05
400.0
50.0
100.0
2
2
2
1
120.0
1
9
8
1
400.0
400.0
3000
3000
1
400.0
sec
sec
Hz
Hz
%
%
-
-
-
-
%
-
-
-
-
A
Ω
Ω
Ω
Ω
mH
mH
A
Ω
Ω
Ω
Ω
mH
mH
A
Hz
Hz
sec
sec
-
Hz
0.00~99.99,100.0~S05 (by 0.01 Hz)
0.1~3000 sec, 0.1~999.9 (by 0.1 sec)
1000~3000 (by 1 sec)
0.1~999.9 (by 0.1 sec)
1000~3000 (by 1 sec)
Multistage speed frequency setting, 2nd motor
Acceleration time, 2nd motor
Deceleration time, 2nd motor
Base frequency, 2nd motor
Maximum frequency, 2nd motor
Manual torque boost setting , 2nd motor
Manual torque boost frequency adjustment, 2nd motor
V/f characteristic curve selection,
2nd motor
Acceleration time 2 setting, 2nd motor
Deceleration time 2 setting, 2nd motor
Acceleration pattern setting, 2nd motor
Deceleration pattern setting, 2nd motor
Electronic thermal setting, 2nd motor
Electronic thermal characteristic,
2nd motor
2nd motor constant setting
2nd motor capacity
2nd motor poles
2nd motor rated current
2nd motor constant R
1
2nd motor constant R
2
2nd motor constant L
2nd motor leakage factor
2nd motor constant Io
2nd motor constant R1 auto-tuning data
2nd motor constant R2 auto-tuning data
2nd motor constant L auto-tuning data
2nd motor constant leakage factor auto-tuning data
2nd motor constant Io auto-tuning data
2-stage accel./decel. transition method setting, 2nd motor
Acceleration transition frequency
setting , 2nd motor
Deceleration transition frequency
setting, 2nd motor
Torque boost mode selection,
2nd motor
0~S 05
S 04~400 Hz
0~50%, manual torque boost voltage setting
0~100%, manual torque boost frequency setting
0: constant torque, 1: reduced torque (1.7)
2: sensorless vector control
0: linear, 1:S-curve, 2: U-curve
0: linear, 1:S-curve, 2: U-curve
0: terminal (2CH), 1: transition frequency (S15, S16)
0.2
×
×
inverter rated current~1.2
×
×
inverter rated current
0: SUB (reduced torque characteristic)
1: CRT (constant torque characteristic)
0: standard motor constants, 1: auto tune data
0~4: 0.4/0.75/.1.5/2.2/3.7kW (220 V)
5~9: 0.4/0.75/.1.5/2.2/3.7kW (440 V)
2/4/6/8
motor rated current
setting range: 0.001~30.00
Ω
Ω
setting range: 0.001~20.00
Ω
Ω
setting range: 0.1~999.9 mH
setting range: 0.01~100.0 mH
setting range: 0.1~100.0 A
setting range: 0.001~30.00
Ω
Ω
setting range: 0.001~20.00
Ω
Ω
setting range: 0.1~999.9 mH
setting range: 0.01~100.0 mH
setting range: 0.1~100.0 A
0.00~99.99 Hz (by 0.01 Hz)
100.0~400.0 Hz (by 0.1 Hz)
0.00~99.99 Hz (by 0.01 Hz)
100.0~400.0 Hz (by 0.1 Hz)
0.1~999.9 (by 0.1 sec)
1000~3000 (by 1 sec)
0.1~999.9 (by 0.1 sec)
1000~3000 (by 1 sec)
0: manual torque boost
1: automatic torque boost
2nd
motor
setting
2nd
motor V/F
chracter-
istic
2nd
motor
acceleration/
deceleration
setting
2nd motor
electronic
thermal
2nd motor
sensorless
vector
control
2nd
motor
constant
Auto-tuning
2nd motor
constant
Function code
Name
Initial value Minimum value Maximum value Unit
Code description
Function List
14 15
Expanded Function S Mode
Содержание hiRUN N100-004HF
Страница 1: ...HEAVY INDUSTRIES CO LTD ...
Страница 2: ...We build a better future ...
Страница 4: ...HYUNDAI INVERTER N100plus ...