3.
OPERATION OF DIESEL GENERATING SET
NOTE 1: If after 3 or 4 attempts the engine does not starts means
that there is air in the fuel circuit, please refer to point 3.2.5 in order
to purge the air.
NOTE 2:Be sure that the circuit or leakage breaker is set in the off
postion, otherwise the machine can be damage
NOTE 3: Do not adjust fuel quantity controller or speed limiter
(having adjusted before delivery). Otherwise, the performance of
the engine will be affected.
3.4.2.2 Remote control Start
a) Place the circuit or leakage breaker to the off/lower position so
no electric power will be given by the machine
b) Leave the Key contactor in OFF position
c) Push the button on the remote control with open lock figure to
start the generator
d) The generator will start automaticly.
e) After 3 minutes running the machine move the circuit or thermal-
breaker to the on/upeer position
f) You machine is ready to be used
NOTE 1: If after 3 or 4 attempts the engine does not starts means
that there is air in the fuel circuit, please refer to point 3.2.5 in order
to purge the air.
NOTE 2: Be sure that the circuit or leakage breaker is set in the off
postion, otherwise the machine can be damage
NOTE 3: Do not adjust fuel quantity controller or speed limiter
(having adjusted before delivery). Otherwise, the performance of
the engine will be affected.
3.4.3 Make the inspection during the operation
a) Check whether there is abnormal sound or strong vibration.
b) Check whether the engine works out of order.
c) Check the color of exhaust gas: black or too white. Black means
the engine is working abnormal or on overload. White means the
mix of air and fuel is not right
3.5 Adding load
a) Add the load according to stipulated data. Please refer to table
4 for detailed loaded data.