3.
OPERATION OF DIESEL GENERATING SET
3.4 Starting & operating the generator
3.4.1 Preparation before starting
Put speed handler of the engine at “RUN” position.
Connect battery electrode as when deliver are not connected
3.4.2 Starting
3.4.2.1 Manual start
a) Place the circuit or leakage breaker to the off/lower position so
no electric power will be given by the machine
b) Pull the starter grip lightly until you feel resistance and them
relase it.
c) Press the decompressor on the top of the cylinder head in order
to reduce the pressure in the cylinder and make easyer pull.
d) Pull briskly
f) Do not allow the starter grip to snap back against the engine.
Return it gently to prevent damage to the starter
g) After 3 minutes running the machine move the circuit or thermal-
breaker to the on/upeer position
h) You machine is ready to be used
NOTE 1: If after 3 or 4 attempts the engine does not starts means
that there is air in the fuel circuit, please refer to point 3.2.5 in order
to purge the air.
NOTE 2: Be sure that the circuit or leakage breaker is set in the off
position, otherwise the machine can be damage
NOTE 3: Do not adjust fuel quantity controller or speed limiter
(having adjusted before delivery). Otherwise, the performance of
the engine will be affected.
3.4.2.2 Electric start
a) Insert the key to OFF position
b) Turn the key to START position clockwise
c) After starting successfuly, remove the hand from the key to
make the key go back to the ON position automatically.
d) If failed to start within 10 seconds holding in START position,
please wait 15 seconds for next starting. If starting motor works
too long, the battery will drop to because the motor to be blocked.
During the operation, let the key be in ON position.
e) After 3 minutes running the machine move the circuit or thermal-
breaker to the on/upeer position
f) You machine is ready to be used
!
CAUTION
OFF
START
ON
OFF
START
STARTER SW
ON
OFF
START
ON
a)
b)
c)
Fig.17 speed handler
at RUN position
Fig.18 speed handler
at STOP position
Fig.19 decompressor