www.hyundaipowerproducts.co.uk
25
Operation
Starting Procedure
1. Fill the tank with diesel (1-K kerosene) until fuel gauge point to “F”.
2. Be sure fuel cap is secure.
3. Plug power cord into the local correct plug. Grounded extension cord and plug extension cord
into three prong 220-240V grounded outlet. The extension cord should be at least six feet (1.8
metres) long.
- Extension cord wire size requirements are as follows:
- 6 to 10 feet (1.8 to 3 metres), use AWG wire.
- 11 to 100 feet (3.4 to 30.4 metres), use 16 AWG wire.
- 101 to 200 feet (30.8 to 61 metres), use 14 AWG wire.
4. Turn thermostat control knob to desired temperature setting. The setting range is from 40°F to
110°F.
5. Press power switch to ON position.
NOTE:
The electrical components of this heater are protected by a fuse mounted in the PC board, if
the heater fails to fire, check the fuse first, and replace if necessary. Also check the power source to
be sure that the proper voltage is being provided to the heater.
Lamp
Thermostat Control
Knob
Power Switch