background image

9.

EC Declaration of conformity

BUILDER

32, rue Aristide Bergès - ZI 31270 Cugnaux – France

Phone: +33 (0)5.34.502.502 Fax: +33 (0)5.34.502.503

declares that the machine designation:

GASOLINE INVERTER GENERATOR

HG4000I-A1

Serial number:

20200719615-20200719814

Is in conformity with the European Directives: Machine Directive 2006/42/EC

This product is in conformity with the following European standards:

Directive 2000/14/EC and 2005/88/EC

EMC Directive 2014/30/EU

This product is also in conformity with the following standards:

Name and address of the noise measuring laboratory:

Signed in Cugnaux

, on 13/05/2020

Philippe MARIE / PDG

Содержание HG4000l-A1

Страница 1: ...WARNING Read thoroughly the instruction manual before use ...

Страница 2: ... do not know these instructions use this device Local regulations may impose restrictions on the age of the user Please do not use this device when people especially children or pets are nearby Direct them away from the working area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get...

Страница 3: ...m an authorised after sales service centre Warning when you start the generator with the cord watch out for sudden changes in the rotation of the motor Risk of wounding Never cover the generator when it is running The cut out mounted on the generator has the aime of reducing the risk of electric shock If it needs to be replaced with another cut out the latter must correspond to the technical speci...

Страница 4: ...ble Security measures when filling the fuel tank The fuel is extremely flammable and poisonous This generator only uses petrol gasoline any other kind of fuel will damage the motor Do not overfill the tank with petrol to avoid spilling If you notice a spill it must be wiped up completely with a dry cloth before starting the motor If you swallow fuel by mistake if you inhale fuel vapours or if you ...

Страница 5: ...or auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in conformity to the provisions of the applicable laws and norms in the field of electricity Incorrect connections will cause leakage of the current from the generator into the lines of the public electricity company Such leakage could electrocute the workers of the public electricity c...

Страница 6: ...k of serious injury or even death This is the safety alert symbol It is used to warn you of a risk of injury and material damage Observe all safety messages following this symbol to avoid possible injury or death or material damage In order to reduce the risk of injury and material damage the user should read and understand this manual before using this product Running the electric generator in a ...

Страница 7: ...Guaranteed noise emission level This symbol indicates the surface is very hot and not touching Exhaust emissions are harmful to health of body No naked fire near the machine Danger Electrical shock ...

Страница 8: ...this owner s manual before operating your generator Familiarize yourself with the location and function of the controls and features Save this manual for future reference Inverter 1 Fuel Cap Remove to add fuel 5 Maintenance Cover ...

Страница 9: ...ered Generator is shipped with the following parts Oil funnel 1 Spark plug socket 1 Automotive style battery charge cables 1 Power Panel 1 Fuel Valve Knob 2 Choke 9 Oil Warning Light Check oil level when this light turns on Engine will not run when indicator is lit 3 Economy Control Switch 10 Overload Indicator Light This light turns ON ...

Страница 10: ... two HG4000i A1 Warning Do not operate a device while it is plugged into the 12 V DC outlet Prolonged exposure to engine exhaust can cause serious injury or death While charging a device do no place on the exhaust side of the generator Extreme heat caused by exhaust can damage the device and cause a potential fire hazard 4 ASSEMBLY Your generator requires some assembly This unit ships from our fac...

Страница 11: ... of 85 and an ethanol content of less than 10 by volume 2 DO NOT mix oil with fuel 3 Clean the area around the fuel cap 4 Remove the fuel cap 5 Slowly add fuel to the tank DO NOT OVERFILL Fuel can expand after filling A minimum of 6 4 mm in of space left in the tank is required for fuel expansion more than 6 4 mm in is recommended Fuel can be forced out of the tank as a result of expansion if it i...

Страница 12: ...ound terminal connected to the frame of the generator has been provided on the power panel For remote grounding connect of a length of heavy gauge 12 AWG minimum copper wire between the generator ground terminal and a copper rod driven into the ground We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes ...

Страница 13: ...er location that will not allow for adequate cooling of the generator and or the muffler DO NOT contain generators during operation Allow generators to properly cool before transport or storage Place the generator in a well ventilated area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents wh...

Страница 14: ...s at normal speed continuously Connecting Electrical Loads 1 Let the engine stabilize and warm up for a few minutes after starting 2 Plug in and turn on the desired 230 Volt AC single phase 50 Hz electrical loads DO NOT connect 3 phase loads to the generator DO NOT connect 60 Hz loads to the generator DO NOT overload the generator 12 V DC Outlet The 12 V DC outlet can be used with the supplied cha...

Страница 15: ...tion 6 Turn the fuel cap lever vent to the Off position after the generator has cooled down completely Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes 1 Select the electrical devices you plan on ...

Страница 16: ...he cover screws and remove the maintenance cover 3 Pop up the rubber maintenance plug from below the drain bolt 4 Remove the 12 mm drain bolt 5 Tilt the generator on its side and allow the oil to drain completely 6 Add 0 6 qt 0 6 L of oil and replace oil fill cap dipstick DO NOT OVERFILL 7 Reinstall the maintenance cover and tighten the cover screws 8 Dispose of used oil at an approved waste manag...

Страница 17: ...he spark arrester if it is damaged 6 Position the spark arrester in the muffler and attach with the two screws Adjustments The air fuel mixture is not adjustable Tampering with the governor can damage your generator and your electrical devices and will void your warranty Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule Service your generator more fr...

Страница 18: ...term storage please follow these guidelines Generator Storage 1 Add a properly formulated fuel stabilizer to the tank 2 Be sure all appliances are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the generator run until fuel starvation has stopped the engine This u...

Страница 19: ... Oil capacity is 0 6 qt 0 6 L DO NOT OVERFILL Please reference the following chart for recommended oil types for use in the generator Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in Maintenance Valve Clearance Intake 0 06 0 12 mm 0 002 0 005 in Exhaust 0 08 0 14 mm 0 003 0 006 in Note Tech bulleti...

Страница 20: ......

Страница 21: ...o the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is o...

Страница 22: ...1 Serial number 20200719615 20200719814 Is in conformity with the European Directives Machine Directive 2006 42 EC This product is in conformity with the following European standards Directive 2000 14 EC and 2005 88 EC EMC Directive 2014 30 EU This product is also in conformity with the following standards Name and address of the noise measuring laboratory Signed in Cugnaux on 13 05 2020 Philippe ...

Страница 23: ... the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information contained therein but a modification will be undertaken without notice if it is recognized as an improvement of the preceding characteristic READ THE MANUAL CAREFULLY BEFORE USING THE MACHINE When o...

Страница 24: ...e before dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is completed on the SWAP Europe site For machines with engine failure from manufacturers BRIGGS STRATTON HONDA and RATO please refer to the following instructions Repairs will be done by approved engine ...

Страница 25: ...necessary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair station The use of a product which would show a defect or a breakage which was not the subject of an immediate report and or repair with the services of SWAP Europe Deterioration linked to transport ...

Страница 26: ......