Generator Maintenance
Make certain that the generator is kept clean and
stored properly. Only operate the unit on a flat, level
surface in a clean, dry operating environment. DO NOT
expose the unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapours.
Use a damp cloth to clean exterior surfaces of the
generator. Use a soft bristle brush to remove dirt and
oil.
Use an air compressor (1724 hPa/25 psi) to clear dirt
and debris from the generator.
Inspect all air vents and cooling slots to ensure that
they are clean and unobstructed.
Storage
The generator should be started at least once every
14 days and allowed to run for at least 20 minutes.
For longer term storage, please follow these
guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the
tank.
2. Be sure all appliances are disconnected from the
generator.
3. Run the generator for a few minutes so the treated
fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few
minutes.
6. The generator needs to cool completely before
cleaning and storage.
7. Remove the spark plug cap, then pull the recoil
grip 3 times to drain the gasoline from the
carburetor jets.
8. Change the engine oil.
9. Remove the spark plug and pour about a
tablespoon of oil into the cylinder. Crank the
engine slowly to distribute the oil and lubricate the
cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct
sunlight.