Table 1. Maintenance Schedule (Continued)
Item
No.
Item
1
day
/
8
hr
8
6
wk/
250
hr
8
3
mo/
500
hr
8
1 yr/
2000
hr
8
Procedure or
Quantity
Specification
2
Use ISO VG 46 (conventional) antiwear (HCE-140) for Standard and Cooler/Freezer configurations. Use
Exxon Univis
®
HVI 26 (synthetic) for Sub-Zero and Corrosion/Washdown configurations.
3
Replace after first 500 hours of service and check every 2000 hours or yearly thereafter.
4
Use Mobilgrease
®
28 synthetic extra-protection grease (clay) for Standard and Cooler/Freezer
configurations.
5
Lubricate every 8 hours only if using in a Corrosive/Washdown environment.
6
No change for the life of the unit.
7
Apply antiseize at installation and check every 2 to 5 hours until nuts/bolts stay tight for an entire 8-hour
shift. Check tightness every 3 months or 500 hours thereafter.
8
Whichever comes first.
X=Check C=Change L=Lubricate
NOTE: Never use steam to clean electrical parts.
8000 SRM 1705
Maintenance Schedule
13