1.  Introduction 

 

 

 

 

The  Hyquest  Solutions

  MagnaRod

  takes  all  the  headaches  out  of  Current  Meter  gauging. 

After  selecting  “Bed”  then  “Surface” 
the  water  depth  is  displayed  along 
with the % depth as the rod is moved 
up  and  down  so  you  can  easily  find 
0.2,  0.4,  0.6,  0.8  or  anything  in 
between.  Then  with  the  press  of  a 
button  it  converts  to  a  Current  Meter 
Counter  equivalent  to  our  existing 
CMCsp,  with  automatic  calculation 
and  display  of  ‘point  velocity’  and 
current  meter  revolutions  after  a  pre-
set  time  interval.  The  device  also 
offers  a  Bluetooth  wireless  interface 
feature for compatible PDA or Pocket 
PC  (compatible  software  also  required).  This  measures  flow  velocity  from  almost  any 
mechanically rotating current meter.  A feature of the device is its ability to "clean" the signal 
and interface directly to a compatible PDA, PocketPC, or other computing device and provide 
serial  data  that  can  be  used  by  the  external  device  to  compute  discharge.    Current  Meters 
fitted with a cat whisker  ball and wire contact to perform a mechanical switch closure can be 
used  with  the  unit  to  produce  a  clean,  noise-free  signal.    The  water  velocity  is  directly 
computed and displayed  on the LCD. The 

MagnaRod

  supports up to  6 current meters with 

each meter having up to 3 rating equations and 3 rotations/sec ranges. 

 
 

 

 

The 

MagnaRod counter 

operates with 3 x AA alkaline 1.5V batteries and comes in a robust 

waterproof  enclosure.      The  commands  are  identical  to  the 

CMCsp

  commands,  so  existing 

third  party  compatible  software  that  has  been  developed,  can  be  used  to  perform  a 
measurement and make operating selections.  The 

MagnaRod

 can operate with current meter 

velocities  from  less  than  0.05  ft/sec  to  more  than  20  ft/sec  for  a  Price  AA  meter.    The 

MagnaRod

 also provides a slow-speed mode to improve measurements with extremely slow 

rotating current meters [velocities less than 0.25 ft/sec].  The 

MagnaRod 

does not need to be 

connected to an external device to operate.  The visual indicators, LCD and internal buzzer of 
the 

MagnaRod

 can be used to make a conventional current meter measurement and compute 

water velocity using look up tables if required. 

As  you  continue  to  read  this  manual,  many  features  and  operating  capabilities  of  the 

MagnaRod

 will be revealed and described. The 

MagnaRod

 is extremely easy to use and yet 

versatile enough to offer selections to operate in a wide variety of scenarios and field settings.  

As  an  added  benefit,  whenever  the 

MagnaRod

  is  inactive,  it  will  automatically  turn  itself 

OFF 

after a preselected period to help conserve the batteries.  To turn it 

ON

, simply press the 

2  buttons  together  and  all  previous  settings  are  restored  ready  for  the  user  to  begin  a 
measurement. 

The 

MagnaRod

 also has an internal serial port that can be used to upgrade the firmware as 

new features become available. 

Содержание MagnaRod MAGD/CMC

Страница 1: ...C HYQUEST SOLUTIONS PTY LTD PO BOX 332 LIVERPOOL B C NSW 1871 AUSTRALIA Phone Int 612 9601 2022 Fax Int 612 9602 6971 Phone Nat 02 9601 2022 Fax Nat 02 9602 6971 Email sales hyquestsolutions com au We...

Страница 2: ...4 Current Meter Counter Operation 8 4 5 Current Meter Counter Menus 9 4 6 Indicator LEDs 12 4 7 Bluetooth Communications 12 4 7 1 Serial Communications Interface 13 4 7 2 Data Conversion Example 15 4...

Страница 3: ...quations and 3 rotations sec ranges The MagnaRod counter operates with 3 x AA alkaline 1 5V batteries and comes in a robust waterproof enclosure The commands are identical to the CMCsp commands so exi...

Страница 4: ...nal to determine if a contact closure has occurred and if successive signals are of the same characteristics The MagnaRod then determines contact closure conditions and either counts the signal closur...

Страница 5: ...ress and hold both buttons to turn on the MagnaRod Power OFF Press and hold both buttons again to turn off the MagnaRod Left Right Button Button Bed TSR Surface Stop CMC Start Up Dn Menu Select Hold T...

Страница 6: ...being measured from the surface down to the current meter The total water depth or Sounding is displayed on the bottom of the screen Depth too small indicates you have moved the rod less than 0 02ft 5...

Страница 7: ...e from the river bed to the current meter shaft when the Top Set Rod is in the lowest position 3 LCD Options allows 3 more LCD selections to be chosen The contrast can vary between 6 light and 24 dark...

Страница 8: ...s pulses are detected 3 When the elapsed timer exceeds the measurement interval and a meter pulse is detected the timer will be stopped The final count elapsed time and the calculated velocity are all...

Страница 9: ...contacts this becomes extremely important since Cat s Whisker contacts offer the poorest quality for marking and counting rotations In Cat s Whisker mode there are 2 speed settings FAST is selected fo...

Страница 10: ...tions on the screen match the equations on your Current Meter calibrations sheets 6 Select Save and Return to go back to the previous menu 7 When More Settings Test is selected 5 more selections becom...

Страница 11: ...e for the magnetic head contact does not apply but can be performed 11 The Spin Test is an elapsed time measurement from the time a meter is spun to when rotation of the meter stops Press Start and th...

Страница 12: ...d IEEE 802 14 that offers a transparent serial port protocol for communication When the MagnaRod is turned On the MagnaRod determines if Bluetooth is installed If available Bluetooth can be enabled an...

Страница 13: ...n such as HyperTerm Commands can be sent to the MagnaRod to perform special functions or select operating modes The following describes the serial data requirements commands and data formats that are...

Страница 14: ...t that is transmitted to the externally connected device can be used to display elapsed time and velocity while the measurement is being performed At the end of the measurement interval or if the T co...

Страница 15: ...uously output a 1 second data display without a time limit The T or I command must be used to terminate the operation V The software version of the MagnaRod is sent in the following manner vX X Exampl...

Страница 16: ...terval time is then used to compute the measured velocity For the Normal mode the 1 second output data format displays the accumulating time interval counts based on a 300 Hz sample rate The following...

Страница 17: ...interface Command Function Performed N Spin Test S Start Spin Measurement subcommand in Spin Test A Stop Spin Measurement subcommand in Spin Test U Buzzer ON Z Buzzer OFF M Magnetic Head Meter C Cat...

Страница 18: ...ove the batteries and any remaining water Allow the unit to dry out completely before reinstalling the batteries There are no user serviceable parts inside the MagnaRod If the unit does not function p...

Страница 19: ...porary immersion Note 60 1 Meter cup width for 6 cups Water Velocity Flow absolute maximum 1 Normal Mode Price AA meter Mag 45 ft s 13 7m s 99o to 204o dwell CatW 22 ft s 6 7m s 10o to 62o dwell Pygmy...

Страница 20: ...er Head 1 NOTES a Measurements and Computations based on the following Rating Table Equations Price AA Meter V 2 2048 0 0178 where V Velocity ft s T T Seconds rotation Pygmy Meter V 0 9604 0 0312 T b...

Страница 21: ...f the spin test the MagnaRod sends a final data string that displays the total number of counts and total time all shown in decimal notation This format makes it easy to copy the final total number of...

Страница 22: ...nds to the total number displayed 3 The maximum number of measured meter contact closures clicks is 999 If the accumulating contact closures continues beyond the maximum data form the count rolls over...

Страница 23: ...in the Accessories folder listed in the Programs list on the desktop Within HyperTerminal and before spinning the meter select Capture Text found in the Windows label Transfer tab When the Capture Tex...

Страница 24: ...Do not import column skip in the Column data format window This will show Skip in the column 1 heading 11 Click on column 3 where the Time data is shown in HEX ASCII and change in the Column data form...

Страница 25: ...response of a current meter created from data in a Spin Test file Spin Test for Meter 1234567 0 10 20 30 40 50 60 70 80 90 100 110 120 130 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 101...

Страница 26: ...wing simple formula Dwell Angle Contact time x 360 Total Time The contact time and total time shown above in the formula are expressed in terms of the number of samples measured at a sample rate of 12...

Страница 27: ...e 27 4 06 INSPECTED __________________ Anthony Gemayel Mechatronics Engineer _____________________________________________________________ The above meter has been calibrated in accordance with AS 377...

Отзывы: