© 2022 HyQuest Solutions
11
Configuration
§
Echotest
: Clicking this button, the signal strength of the 433 MHz near field radio connection will be tested. Data
packages will be sent, until the test is aborted manually by the user.
§
Update Logger Firmware
: Perform an update of the logger’s firmware. After a security prompt, new firmware files can
be selected a transferred to the logger. Please refer to the chapter “Updates” for further information.
§
Update USB-Dongle Firmware
: Perform an update of the USB-dongles firmware. After a security prompt, new
firmware files can be selected and transferred to the USB-dongle. Please refer to the chapter “Updates” for further
information.
§
All Radio OFF
: All loggers in range of the dongle will be set to 'flight mode', so the they will not send any more data.
Important
: The loggers will also disappear from the list in GP-Shell.
§
All Radio ON
: All loggers in range of the dongle will be set from 'flight mode' back to 'normal mode'.
3.1.3
Main Window
§
Identify Logger
: Establishes a connection to a logger. To connect to a logger, select a logger from the list before clicking
“Identify Logger”.
§
Synchronize Clock
: Synchronizes logger time with time of the current system.
§
Display Measure
: Show current measurement values (status of logger and measured values of the activated measuring
probe). The values measured when clicking this button will not be stored and not be transmitted to the server, but can
be used for local calibration of data loggers.
§
Load to Disk
: Download measured values from the data logger to your local computer. You can choose between
incremental download (only values that have not been transmitted to the server yet will be downloaded) and full
download (all values stored on the logger will be downloaded). The local path for saving the data can be set in the
setup menu (see
).
§
Attention
: If the modem of the logger is switched off, any data downloaded to your computer will be marked as sent
and will not be transmitted during the next GPRS-transmission. In doing so, the loggers can be operated even without
the use of the GPRS-connection.
§
Clear Logger
: By clicking this button, the whole memory of the logger will be cleared. (All measured data will be
deleted!)
§
Parameters
: Opens a menu for configuring a logger. The logger must be identified first.
§
Data from Disk
: Open Files that have been downloaded to the local computer previously, i.e. measured values (i.e.
*.g2p files).
§
Exit
: Closes the application.