12
HTDF366 – Affluent Series Range Installation
www.hypotheory.com
Electrical Oven Installation/Electrical Power Supply Connection:
The installation,
debugging, connection & power supply on all HypoTheory 220 volt based electrical
appliances/ or appliances that require wiring configuration must be installed by a licensed
electrician. Each oven supplies a terminal that is compatible to connect to a standard 4 or
3 prong 220/240 volt range cord(sold separately). The rated power of the power supply
should be compatible with a standard 220v/60hz or 220 v/50hz system. The minimum
amp required is 35 amp per breaker (per hot wire)- that is 70 amp total. There are two
wiring configuration options shown below to power the range.
3 Wire Configuration (shown above):
The electrician can install wiring around the
screws or use a standard 3 prong range
cord connection. Please ensure the
terminal washers are resting on top of each
wire in order to conduct electricity to the
range. The two hot wires should individually
connect to the cord/wiring hot wires, the
one neutral wire should connect to the
cord/wiring neutral wire, the ground wire
should connect to the cord/wiring ground
wire. Please ensure all connections are
tight, and ensure the proper screw driver is
used, do not over tighten The
neutral/ground wire must be connected to
the service panel. If there is no ground the
strap will act as a ground shown above.
4 Wire Configuration (shown above):
The electrician can install wiring around the
screws or use a standard 4 prong range
cord connection. Please ensure the
terminal washers are resting on top of each
wire in order to conduct electricity to the
range. The two hot wires should individually
connect to the cord/wiring hot wires, the
one neutral wire should connect to the
cord/wiring neutral wire, the ground wire
should connect to the cord/wiring ground
wire. Please ensure all connections are
tight, and ensure the proper screw driver is
used, do not over tighten The
neutral/ground wire must be connected to
the service panel.