3-8
S
ETUP
Operator Manual
Three-Phase 208/240/480V and 600V
Remove the rear panel (Fig. 3-2) and connect the power cable to terminal block TB1 as shown in
Fig. 3-10A. Connect the ground wire to the stud marked above the terminal block. .
Three-Phase 400V CE
Remove the rear panel (Fig. 3-2) and connect the power cable to terminal block TB1 as shown in
Fig. 3-10C. Connect the ground wire to the stud marked above the terminal block. .
Three-Phase 200/230/400V
Remove the rear panel (Fig. 3-2) and connect the power cable to terminal block TB1 as shown in
Fig. 3-10B. Connect the ground wire to the stud marked above the terminal block. .
3-96
Figure 3-10A
Three-Phase Power
208/240/480V
Conductor
Color
Ground
Green
L3
Red
L2
White
L1
Black
Black
Green
TB1
Red
White
Figure 3-10B
Three-Phase Power
200/230/400V
Conductor
Color
Ground
Green/Yellow
L3 (W)
Black
L2 (V)
Blue
L1 (U)
Brown
Brown
Blue
Black
Green/Yellow
TB1
Conductor
Color
Ground
Green/Yellow
L3 (W)
Black
L2 (V)
Blue
L1 (U)
Brown
Note: See also EMC
Compatibility and
Mains
Supply on page i for further
power (supply) cable
shielding recommendations
for CE compliance.
TB1
Green/
Yellow
V
Blue
U
Brown
W
Black
(Filter Board)
Figure 3-10C
Three-Phase Power
400V CE