D
ESCRIPTION
& S
PECIFICATIONS
2-3
Operator Manual
SPECIFICATIONS
Power Supply
Rated Open Circuit Voltage (OCV) (U
0
) ............... 300 VDC
Rated Output Current (I
2
) ..................................... 20–50 amps
Rated Output Voltage (U
2
) .................................... 120 VDC
Duty Cycle (X) @ 40
°
C ......................................... 50% (I
2
=50A, U
2
=120V)
100% (I
2
=35A, U
2
=120V)See data tag on power
supply for more information on duty cycle
Ambient temperature/duty cycle ........................... Power supplies will operate b14
°
and
104
°
F (-10
°
and +40
°
C). Power supplies
operated in an ambient temperature above 86
°
F
(30
°
C) may show some decrease in duty cycle.
Apparent Input Power (S
1
) .................................... 10.4kVA (U
1
I
1
)
Input Voltage (U
1
)/Input Current (I
1
)
@ 6 kw Output ...................................................... 208V/50A; 240V/43A; 480V/25A - 1
φ
, 60 Hz
208V/29A; 240V/25A; 480V/13A - 3
φ
, 60 Hz
200V/52A; 230V/45A; 400V/30A - 1
φ
, 50/60 Hz
200V/30A; 230V/26A; 400V/16A - 3
φ
, 50/60 Hz
400V (CE)/16A - 3
φ
, 50/60 Hz
600V/11A - 3
φ
, 60 Hz
Dimensions and Weight:
Depth .................................................................... 23.1" (590 mm)
Width .................................................................... 10.4" (260 mm) without wheels
15.3" (390 mm) with wheels
Height ................................................................... 19.6" (500 mm) without wheels
23.7" (620 mm) with wheels
27.7" (700 mm) for 600V power supply
Figure 2-2 Powermax800 Power Supply with Dimensions
10-96
23.1"
19.6"
10.4"