TroubleshooTing and sysTem TesTs
5-26
powermax
65/85
Service Manual
Fault
code
Description
(
System test number)
Power
LED
Fault
LED
Fault
icon
Solutions
0-50-0 Retaining cap off
(Test 8)
On
On
• Verify that proper consumables and retaining
cap are installed. Replace damaged parts.
Refer to section
Torch Setup
.
• With the retaining cap installed, check for
continuity between pins 5 and 7 at the torch
connector.
• If the consumables appear to be installed
correctly, the torch may be damaged. Test
with a known working torch.
• After correcting the problem, perform a cold
restart.
0-51-0 Start/trigger signal on at
power up
(Test 7)
This situation indicates that
the power supply is receiving
a start signal at power-up. It
is sometimes referred to as a
“stuck start.”
On
On
If the power supply is turned on while the torch
trigger is pressed, the system is disabled.
• Release the trigger and cycle the power to
the machine.
• Check for continuity between Pin 6 and Pin
7 of the torch connector. There should be
very low resistance when the torch trigger is
pulled.
• Test with a known working torch.
0-52-0 Torch not connected
On
On
• Plug a torch lead into the FastConnect
receptacle on the front of the power supply
and recycle the power switch.
0-60-0 Phase loss
(Test 1)
On
On
Wear proper personal protection equipment
when checking the voltage.
• Check for proper voltage (phase to phase
and phase to ground) at the power source
and at the machine.
0-60-1 Under voltage
(Test 1)
• Increase the supply voltage.
0-60-2 Over Voltage
(Test 1)
• Decrease the supply voltage.
0-61-0 AC input unstable:
Shutdown
On
On
• Test the machine from another AC power
source.
• Power down and correct the line resonance
problem before continuing.
Содержание Powermax 65
Страница 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Страница 10: ...vi powermax65 85 Service Manual ...
Страница 16: ...Table of Contents xii powermax65 85 Service Manual ...
Страница 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Страница 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Страница 200: ...Component Replacement 6 18 powermax65 85 Service Manual 1 4 6 2 3 3 3 5 DSP back view DSP front view ...
Страница 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Страница 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...
Страница 247: ...8 5 Electrical schematic diagram CSA ...
Страница 248: ...8 6 Electrical schematic diagram CE ...