Work lead
receptacle
on power supply
Keyed opening at
top of
receptacle
1. Insert the work lead connector into the receptacle on the front of the power supply.
Note: The receptacle is keyed. Align the key on the work lead connector with the opening at the top of the
receptacle on the power supply.
Caution: Make sure you use a work lead that is appropriate for your power supply.
Use a 65 A work lead with the Powermax65. Use an 85 A work lead with the
Powermax85. The amperage is marked near the rubber boot of the work lead
connector.
2. Push the work lead connector all the way into the receptacle on the power supply and turn clockwise, approximately
1/4 turn, until the connector is fully seated against the stop in order to achieve an optimal electrical connection.
Attach the work lead to the power supply
Caution: Ensure the work lead is fully seated in the receptacle to prevent overheating.
Содержание Powermax 65
Страница 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Страница 10: ...vi powermax65 85 Service Manual ...
Страница 16: ...Table of Contents xii powermax65 85 Service Manual ...
Страница 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Страница 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Страница 200: ...Component Replacement 6 18 powermax65 85 Service Manual 1 4 6 2 3 3 3 5 DSP back view DSP front view ...
Страница 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Страница 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...
Страница 247: ...8 5 Electrical schematic diagram CSA ...
Страница 248: ...8 6 Electrical schematic diagram CE ...