Troubleshooting preparation
The complexity of the circuits requires that service technicians have a working knowledge of inverter power supply
theory. In addition to being technically qualified, technicians must perform all testing with safety in mind.
If questions or problems arise during servicing, call the Hypertherm Technical Services team listed in the front of this
manual.
Test equipment
• Multimeter
• IGBT (insulated gate bipolar transistor) tester (part number 128883)
Troubleshooting procedures and sequence
When performing the troubleshooting procedures:
• Read the
Safety and Compliance Manual
(80669C) for detailed safety information.
• Refer to Section 6,
Component Replacement
.
• Refer to Section 7,
Parts
.
• Refer to Section 8,
Wiring Diagrams
.
After the problem has been located and repaired, refer to the “Sequence of operation” flow diagram in this section to
test the power supply for proper operation.
Power OFF and disconnected
External inspection
Power ON
Internal inspection
Resistance checks
Troubleshooting guide
and
Fault
codes
sections
Troubleshooting tests
Содержание Powermax 65
Страница 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Страница 10: ...vi powermax65 85 Service Manual ...
Страница 16: ...Table of Contents xii powermax65 85 Service Manual ...
Страница 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Страница 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Страница 200: ...Component Replacement 6 18 powermax65 85 Service Manual 1 4 6 2 3 3 3 5 DSP back view DSP front view ...
Страница 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Страница 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...
Страница 247: ...8 5 Electrical schematic diagram CSA ...
Страница 248: ...8 6 Electrical schematic diagram CE ...