TORCH SeTUP
3-44
powermax
65/85
Operator Manual
85A Unshielded
Air flow rate - slpm/scfh
Mild Steel
Hot
190 / 400
Cold
235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.0
7150
117
13000
113
3
0.1
6240
118
11200
114
4
0.2
5250
118
9000
117
6
0.5
3450
120
5500
120
8
2400
121
3900
121
10
1560
123
2600
122
12
6.0
300
0.7
1200
126
2000
124
16
Edge Start
820
132
1150
126
20
540
137
800
131
25
320
143
500
137
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
14GA
0.08
0.20
250
0.1
300
116
540
112
10GA
0.2
280
117
520
112
3/16 in
230
118
410
115
1/4 in
0.5
175
119
275
119
3/8 in
125
120
200
120
1/2 in
0.24
300
0.6
65
122
108
122
5/8 in
Edge Start
42
127
70
124
3/4 in
33
131
46
126
7/8 in
23
136
34
130
1 in
18
140
26
134
Содержание Powermax 65
Страница 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Страница 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Страница 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Страница 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...