OPERATION
4-26
HySpeed HT2000LHF
Instruction Manual
7
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (CO
2
)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(N
2
%)
(N
2
%)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (CO
2
)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(N
2
%)
(N
2
%)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
3/16
5
50
60
60
1/8
3
1/4
6
130
185
4700
0.5
1/4
6
(66.4
(79.6
(210
1/8
3
1/4
6
135
160
4050
1.0
3/8
10
SCFH)
SCFH)
SCFH)
1/8
3
1/4
6
135
120
3050
2.0
1/2
12
1/8
3
1/4
6
140
95
2400
2.5
5/8
15
.157
4
.314
8
140
70
1800
2.5
3/4
20
3/16
5
3/8
10
150
55
1400
3.0
7/8
22
1/4
6
1/2
12
160
42
1050
3.0
1
25
1/4
6
165
33
840
1-1/4
32
`
1/4
6
175
20
510
1-1/2
38
5/16
8
185
11
280
Aluminum
200 amps • N
2
Plasma / CO
2
Shield
This gas combination is used when cut edge quality is less important. Electrode life is extended when this
combination is used.
Notes:
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
Production cutting above 7/8" (22 mm) not recommended
Above Water
3/16
5
50
60
60
1/8
3
1/4
6
130
175
4450
0.5
1/4
6
(66.4
(79.6
(220
1/8
3
1/4
6
135
145
3650
1.0
3/8
10
SCFH)
SCFH)
SCFH)
1/8
3
1/4
6
140
100
2600
2.0
1/2
12
1/8
3
1/4
6
145
75
1820
2.5
5/8
15
.157
4
.314
8
145
55
1350
2.5
3/4
20
3/16
5
3/8
10
155
40
980
3.0
7/8
22
1/4
6
1/2
12
165
30
750
3.0
3" Under Water
020424
Shield
120837
Retaining cap
020608
Nozzle
020607
Swirl ring
020415
Electrode
Содержание HT2000LHF
Страница 1: ...200 Volt Plasma Arc Cutting System Instruction Manual 803040 Revision 7 HySpeed HT2000LHF ...
Страница 5: ......
Страница 15: ...TABLE OF CONTENTS viii Hyspeed HT2000LHF Instruction Manual 6 ...
Страница 109: ...MAINTENANCE 5 20 HySpeed HT2000LHF Instruction Manual 7 ...
Страница 133: ......
Страница 134: ...7 5 7 Figure 7 1 HT2000LHF Coolant Flow Diagram ...
Страница 135: ......
Страница 136: ...7 7 7 ...
Страница 137: ......
Страница 138: ...7 9 7 ...
Страница 139: ......
Страница 140: ...7 11 7 ...
Страница 141: ......
Страница 142: ...7 13 7 ...
Страница 143: ......
Страница 144: ...7 15 7 ...
Страница 145: ......
Страница 146: ...7 17 7 ...
Страница 147: ......
Страница 148: ...7 19 7 ...
Страница 149: ......
Страница 150: ...7 21 7 ...
Страница 151: ......
Страница 152: ...7 23 7 ...
Страница 153: ......
Страница 154: ...7 25 7 ...
Страница 155: ......
Страница 157: ......
Страница 159: ......
Страница 174: ...APPENDIX A ARGON HYDROGEN CUTTING AND GOUGING a 14 HySpeed HT2000LHF Instruction Manual 6 ...
Страница 176: ...b 2 ...
Страница 177: ...b 3 ...
Страница 178: ...b 4 ...
Страница 179: ...b 5 ...
Страница 181: ...b 7 ...
Страница 182: ...b 8 ...
Страница 183: ...b 9 ...
Страница 184: ...b 10 ...
Страница 194: ...APPENDIX E AIR FILTERS e 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Страница 196: ...APPENDIX F AERATION MANIFOLD FOR CUTTING ALUMINUM f 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Страница 198: ...APPENDIX G IEC SYMBOLS g 2 Hyspeed HT2000LHF Instruction Manual 6 ...