OPERATION
3-12
Duramax Retrofit Torch
Operator Manual
40 amp mechanized unshielded consumables
• Torch-to-work dis tance for the following cut chart is 1.5 mm (1/16 inch) for all cuts.
220955
Deflector
220854
Retaining cap
220857
Swirl ring
220842
Electrode
220941
Nozzle
45
A
Mild Steel
Arc
Current
Arc
Voltage
Motion
Delay
Material Thickness
Maximum Travel Speeds
Optimum Travel Speeds
Inches
mm
IPM
mm/min
IPM
mm/min
25
125
0
26 GA
0.5
550
13970
353
8966
128
22 GA
0.8
484
12294
315
8001
130
18 GA
1.3
238
6045
155
3937
131
16 GA
1.5
167
4242
109
2769
40
129
0.25
14 GA
1.9
326
8280
212
5385
Stainless
Arc
Current
Arc
Voltage
Motion
Delay
Material Thickness
Maximum Travel Speeds
Optimum Travel Speeds
Inches
mm
IPM
mm/min
IPM
mm/min
25
127
0
26 GA
0.5
561
14249
365
9271
127
22 GA
0.8
453
11506
295
7493
40
123
0.25
18 GA
1.3
500
12700
325
8255
127
16 GA
1.5
367
9322
239
6071
128
14 GA
1.9
220
5588
143
3632
Aluminum
Arc
Current
Arc
Voltage
Motion
Delay
Material Thickness
Maximum Travel Speeds
Optimum Travel Speeds
Inches
mm
IPM
mm/min
IPM
mm/min
25
125
0
1/32
0.8
564
14326
366
9296
127
1/16
1.5
236
5994
153
3886
40
127
0.25
3/32
2.4
261
6629
170
4318
Содержание Duramax Series
Страница 2: ......
Страница 10: ......
Страница 30: ...Torch setup 2 16 Duramax Retrofit Torch Operator Manual ...