OPERATION
3-6
Duramax Retrofit Torch
Operator Manual
45A Shielded
Air flow rate - slpm/scfh
Stainless Steel
Hot
177 / 376
Cold
201 / 427
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
0.5
1.5
3.8
250
0.0
9000
130
12500
129
1
9000
130
10800
130
1.5
0.1
9000
130
10200
130
2
0.3
6000
132
8660
131
3
0.4
3100
132
4400
132
4
2000
134
2600
134
6
0.5
900
140
1020
139
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
inches
inches
%
seconds
ipm
Volts
ipm
Volts
26GA
0.02
0.08
400
0.0
350
130
500
129
22GA
350
130
450
129
18GA
0.1
350
130
400
130
16GA
350
130
400
130
14GA
0.06
0.15
250
0.2
250
132
360
131
12GA
0.4
140
132
206
131
10GA
100
133
134
134
3/16 in.
0.5
52
135
58
135
1/4 in.
0.6
30
141
35
140
220817
Shield
220854
Retaining cap
220941
Nozzle
220857
Swirl ring
220842
Electrode
45
A
220817
Shield
220941
Nozzle
220857
Swirl ring
220842
Electrode
220953
Ohmic-sensing
retaining cap
45
A
Содержание Duramax Series
Страница 2: ......
Страница 10: ......
Страница 30: ...Torch setup 2 16 Duramax Retrofit Torch Operator Manual ...