OPERATION
3-10
Duramax Retrofit Torch
Operator Manual
45A Unshielded
Air flow rate - slpm/scfh
Stainless Steel
Hot
177 / 376
Cold
201 / 427
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
0.5
1.5
3.8
250
0.0
9000
121
12500
119
1
9000
121
10800
119
1.5
0.1
9000
121
10200
120
2
0.3
6000
122
9600
120
3
0.4
3250
123
4750
120
4
1900
128
3000
122
6
0.5
700
130
1450
124
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
inches
inches
%
seconds
ipm
Volts
ipm
Volts
26GA
0.02
0.08
400
0.0
350
120
500
119
22GA
350
120
450
119
18GA
0.1
350
118
400
119
16GA
350
121
400
120
14GA
0.06
0.15
250
0.2
300
122
400
120
12GA
0.4
150
121
224
120
10GA
100
125
140
121
3/16 in.
0.5
42
131
88
123
1/4 in.
0.6
25
130
48
124
220955
Deflector
220854
Retaining cap
220857
Swirl ring
220842
Electrode
220941
Nozzle
45
A
Содержание Duramax Series
Страница 2: ......
Страница 10: ......
Страница 30: ...Torch setup 2 16 Duramax Retrofit Torch Operator Manual ...