background image

 

EMETER BASIC SETUP 

continued

 

 

Function Screen/Mode 

 

1.3  Screen Backlight 

MAIN>EMETER SETUP 

 

Press ‘D’ to move to LCD Light line and pick 
‘Off’ for no backlight 
‘On’ for constant backlight 
‘Auto’ for backlight on for 10 seconds duration whenever a button is pushed                  Default setting is ‘Auto’. 

1.4  Contrast MAIN>EMETER 

SETUP 

 

Press ‘D’ to move to Contrast and pick a number between 15 and 30 for desired effect. 

1.5  Button Beeps 

MAIN>EMETER SETUP 

 

Press ‘D’ to move to Beeps and pick ‘On’ or ‘Off’ for a ‘click’ or ‘beep’ each time a button is pressed . Default setting is ‘On’. 

1.6  Height & Temperatures 

MAIN>EMETER SETUP 

 

System holds figures in Metres and Celsius and will convert and display Feet and Fahrenheit if so specified here. 

 

INSTANTANEOUS READINGS 

(and Tacho Setup)

 

 

Function Screen/Mode 

Cables/Wiring 

2.1 

Tacho -  configure Optical Tach 

READINGS>TACHO>push ‘C’ > CONFIG TACHO 

None 

Set Tacho Source as Emeter by pressing ‘B’ or ‘C’. Press ‘D’ and set blades as 1 to 6. 
Without the RDU connected, the source will be set to Emeter automatically. 
--  Set Tacho averaging: 

On

 averages rpm over 2 secs if < 9,000 rpm.  Averages rpm over 1 sec if > 9,000 rpm 

Off 

averages over 1 sec always.                                                                           Press ‘A’ to save tacho configuration 

2.2 

Tacho: configure Phase Sen. 
Tach 

READINGS>TACHO>push ‘C’ > CONFIG TACHO 

*The RDU Tacho is for brushless motors and ESC only * 

 

RDU + RDU cable +  
Phase Tach 

With the Emeter II, RDU and the phase sensor pick-up lead connected, the source can be selected as either  

 

Emeter II for the optical tacho or 

 

RDU for the phase sensor tacho 

 

For RDU, the number of Motor Magnets must be set or erroneous results will occur.  Set Gearbox ratio (“1” for direct drive) 

2.3 

Determine Motor Magnet Count 

READINGS>TACHO push ‘C’ > CONFIG TACHO 
 

RDU + RDU cable +  
Phase Tach  

Run the motor at steady speed with Emeter II close to spinning prop. 
Vary no. of magnets until the RDU and Emeter II Opto rpm figures match and Save configuration. 

2.4

 

Tacho - Read RPM optical 

READINGS>TACHO 

None 

Hold top of Emeter II about 10 cm from rotating prop. Wait until readings steady. Avoid fluorescent lights 
Press ‘D’ to hold reading (see sect 4.1).  Press ‘C’ to save reading to SNAPSHOT 1-8 (see section 4.3) 
Press ‘B’ to set prop constants, if known and show motor output power (see section 5) 

2.5 

Tacho – Read phase sensor RPM 

READINGS>TACHO or 
READINGS>ANALYSER 

RDU + RDU cable  
+ rpm sensor cable 

Connect rpm sensor lead to RDU RPM socket and to any of the 3 wires of brushless motor. * Do not use on brushed motors * 

2.6 

Read Volts Bench-Test 

READINGS>ANALYSER 

RDU + RDU cable 

0 to 70 volts,  2 dec. places 

2.7 

Read Amps Bench-Test 

READINGS>ANALYSER 

RDU + RDU cable 

0 to 150 amps peak, 1 dec. place. BATTERY shows voltage, max. and min. and ma-h energy input and output (charge & 
discharge) 

2.8 

Watts into ESC/Motor 

READINGS>ANALYSER 

RDU + RDU cable 

0 - 10000 watts, calculated as the product of Volts * Amps 

2.9 

Motor/ESC Efficiency 

READINGS>ANALYSER 

RDU + RDU cable 

Displays efficiency if Prop Constants in place and less than 100%.  Press ‘D’ to hold values on screen. Press ‘C’ to save values 
in SNAPSHOT 1–8 

2.10 

Motor Output Power & Thrust 

READINGS>TACHO 

None 

Display power in Watts and BHP and thrust in grams if propeller constants exist for the given prop. 

2.11 

Height 

READINGS>ANALYSER 

RDU + RDU cable 

The height sensor is fitted in the RDU and is set to zero metres when power is connected to the RDU. Position in model may 
affect readings. See Emeter II manual for more. 

 

Содержание Emeter II

Страница 1: ...from some old toy router etc Please take time now to fit appropriate connectors to this cable and plug in your Emeter to a 12 15V power source for charging See details below for charge rate and time T...

Страница 2: ...t cases A will cause a return to the previous higher menu item or screen Certain actions may cause deletion of data which could be critical You will be warned if this is the case and requested to conf...

Страница 3: ...Set Gearbox ratio 1 for direct drive 2 3 Determine Motor Magnet Count READINGS TACHO push C CONFIG TACHO RDU RDU cable Phase Tach Run the motor at steady speed with Emeter II close to spinning prop V...

Страница 4: ...Snapshots are retained when the Emeter II is turned off but for long term data retention see data logging facility 4 3 Snapshot Recall Clear READINGS SNAPSHOTS None Shows up to 8 snapshots taken from...

Страница 5: ...DU optional RPM and temperature sensors NO RDU cable from RDU to Emeter II 3 wire cable from spare Rx channel to RDU Rx input for manual logging start Connect optional rpm sensor to RDU RPM port and a...

Страница 6: ...her Emeter II functions such as Tacho or servo test without interrupting the countdown At the end of the specified time A 3 second long beep will sound even if the Emeter II is in use on a different s...

Страница 7: ...le is to be executed Continuously or Once Only LOGGING Yes No Turns logging ON of OFF during the test run as desired THE FOLLOWING PARAMETERS WILL AUTO TERMINATE THE TEST according to your settings an...

Страница 8: ...hing power to Emeter II SD card Firmware loader process checks for file EMFW bin on SD card and if found loads the new firmware version into the Emeter II 9 4 Upgrade RDU Firmware version MAIN RDU SET...

Страница 9: ...f BEC ESC and a Brushless Motor 4 wire RDU to Emeter Data cable B C A Connect to Emeter Servo Driver Port To BEC ESC Also see http media hyperion hk dn em2 bottom of page for the Emeter II Suite PC So...