background image

 

ACCUMULATED and PEAK DATA 

 

Function Screen/Mode 

Cables/Wiring 

3.1 

Capacity mAh Input 

READINGS>BATTERY or READINGS>ANALYSER 
Accumulates even when on other screens 

RDU + RDU cable 

From 0 – 65000 mA-h.  Records charged capacity automatically, whenever current is flowing through the RDU. Press ‘C’ to clear 
mA-h In when on BATTERY screen.  NOTE: Capacity will continue to log in the RDU even if the Emeter II is switched off. 

3.2 

Capacity mAh Output 

READINGS>BATTERY or READINGS>ANALYSER 
Accumulates even when on other screens 

RDU + RDU cable 

From 0~65000 mA-h.   Records discharged capacity automatically, whenever current is flowing through the RDU. Press ‘C’ to clear 
mA-h ‘Out’ when on BATTERY screen.  Note:  Capacity will continue to log in the RDU even if the Emeter II is switched off. 

3.3 

Max Volts 

READINGS>PEAKS 

RDU + RDU cable 

Peak values recorded for whole session or from when ‘B’ (Clr) pressed. These values are lost when switching the Emeter II off 
unless saved to SNAPSHOT 1 – 8 

3.4 

Min Volts 

READINGS>PEAKS 

RDU + RDU cable 

As above. Useful to assist in protecting batteries from over-discharge. 

3.5 

Max Amps 

READINGS>PEAKS 

RDU + RDU cable 

As above.  Useful to assist in protecting batteries and ESC from over-current conditions. 

3.6 

Max RPM 

READINGS>PEAKS 

RDU + RDU cable 

Peak values recorded for whole session or until   ‘B’ (Clr) pressed. 

3.7 

Pack resistance Ohms 

READINGS>PEAKS 

RDU + RDU cable 

Start discharge, press   ‘B’ (Clr), stop discharge or Press ‘B’ (Clr), start and stop discharge. Resistance will be shown in ohms 

SNAPSHOTS 

for short term saving of readings

 

4.1 

Hold Display  

On TACHO, PEAKS, ANALYSER, BATTERY screens 

RDU + RDU cable 

Press  ‘D’ to hold – 2

nd

 press continues,  as if no hold took place 

4.2 

Save snapshot  

As for Hold 

RDU + RDU cable 

Press  ‘C’ to save in one of 8 SNAPSHOT locations for later recall, select SNAPSHOT 1 to 8 by pressing ‘D’, if required.  
 
Press ‘C’ again to resume original activity. Data stored in first empty SNAPSHOT location by default. Snapshots are retained when 
the Emeter II is turned off, but for long term data retention, see data logging facility 

4.3 

Snapshot Recall-Clear   READINGS>SNAPSHOTS 

None 

Shows up to 8 snapshots taken from ANALYSER, BATTERY, SNAPSHOTS or TACHO screens These are stored internally, not on the 
SD card. Press ‘D’ to scroll through snapshot 1 to 8.  Display is in format of screen from which the save was originally made. 
For ANALYSER or TACHO data press ‘B’ to view or specify Prop. constants. If these exist, then the calculated efficiency and/or 
propeller thrust in grams will show.  Clear snapshot by pressing  ‘C’ 

PROP CONSTANTS 

for calculation of motor efficiency and thrust

 

 

Function Screen/Mode 

Cables/Wiring 

5.1 

Prop Constant Background 

 

 

Prop constants can be used to calculate motor/ESC power/efficiency and also thrust for given RPM. See PROP TALK tutorial in 
Hyperion Website at www.hyperion.hk/dn/em2 .  Emeter II can look up prop constants from a PROPS.TXT file held on the SD Card 
or will accept constants entered manually onto the CONSTANTS screen. The latter are given the name ‘Other’. For either case, the 
last-used propeller details are retained for subsequent power, efficiency and thrust calculations 

5.2 

Prop Constant Viewing 

READINGS>PROP CONST or 
READINGS>ANALYSER> button ‘B’ (Prop) or 
READINGS>TACHO> button ‘B’ (Prop) 

SD Card 

If SD Card contains PROPS.TXT file, browse props via buttons ‘B’  (Dec) and ‘C’ (Inc). To select required file press ‘A’ (Save) 

5.3 

Prop Constant Entry 

READINGS>PROP CONST or 
READINGS>ANALYSER> button ‘B’ (Prop) or 
READINGS>TACHO> button ‘B’ (Prop) 

 

Press ‘D’ (next) to move to Power Constant field, use ‘D’ to move to figure to be entered and ‘B’ or ‘C’ to change to required value. 
Use ‘D’ to move to next figure and repeat process in the same way. Once numbers are correct, press ‘A’ to save for all future 
calculations until changed and saved again.  Prop name will change to ‘Other’ 

5.4 

Prop Constant Entry Notes 

 

 

Motor output power, efficiency and thrust figures are not calculated for In-Action mode since propeller constants do not apply to 
moving models. Only Bench-test mode can record power, efficiency and thrust.   See manual for details. 

 

Содержание Emeter II

Страница 1: ...from some old toy router etc Please take time now to fit appropriate connectors to this cable and plug in your Emeter to a 12 15V power source for charging See details below for charge rate and time T...

Страница 2: ...t cases A will cause a return to the previous higher menu item or screen Certain actions may cause deletion of data which could be critical You will be warned if this is the case and requested to conf...

Страница 3: ...Set Gearbox ratio 1 for direct drive 2 3 Determine Motor Magnet Count READINGS TACHO push C CONFIG TACHO RDU RDU cable Phase Tach Run the motor at steady speed with Emeter II close to spinning prop V...

Страница 4: ...Snapshots are retained when the Emeter II is turned off but for long term data retention see data logging facility 4 3 Snapshot Recall Clear READINGS SNAPSHOTS None Shows up to 8 snapshots taken from...

Страница 5: ...DU optional RPM and temperature sensors NO RDU cable from RDU to Emeter II 3 wire cable from spare Rx channel to RDU Rx input for manual logging start Connect optional rpm sensor to RDU RPM port and a...

Страница 6: ...her Emeter II functions such as Tacho or servo test without interrupting the countdown At the end of the specified time A 3 second long beep will sound even if the Emeter II is in use on a different s...

Страница 7: ...le is to be executed Continuously or Once Only LOGGING Yes No Turns logging ON of OFF during the test run as desired THE FOLLOWING PARAMETERS WILL AUTO TERMINATE THE TEST according to your settings an...

Страница 8: ...hing power to Emeter II SD card Firmware loader process checks for file EMFW bin on SD card and if found loads the new firmware version into the Emeter II 9 4 Upgrade RDU Firmware version MAIN RDU SET...

Страница 9: ...f BEC ESC and a Brushless Motor 4 wire RDU to Emeter Data cable B C A Connect to Emeter Servo Driver Port To BEC ESC Also see http media hyperion hk dn em2 bottom of page for the Emeter II Suite PC So...

Отзывы: