START
V
D D
= 6.0V
V
PP
= 12.5V
X = 0
P R O G R A M O N E 1 m s P U L S E
INCREMENT X
VERIFY
BYTE
VERIFY
ONE BYTE
LAST
ADDRESS ?
V
D D
= V
PP
= 5.0V
C O M P A R E
ALL BYTES TO
ORIGINAL
DATA
DEVICE PASSED
INCREMENT
ADDRESS
YES
NO
FAIL
PASS
FAIL
PASS
NO
YES
FAIL
PASS
DEVICE FAILED
PRO G RAM O N E PU LSE
OF 3X msec DURATION
X = 25 ?
ADDRESS= FIRST LOCATION
Intelligent Programming Algorithm
GMS81516AT EPROM PROGRAMMING HYUNDAI MicroElectronics
13