(ARCON TEST)&SET:
1
、
stop work status: press and hold it to test the arc start, press it until the plasma arc start, loose it
plasma arc stop.
2
、
setting status: press it one time to set parameters(SET)
UP/DOWN
:
Stop work status: control the torch to go up and go down;
Auto work status: adjust the setting arc voltage, means to change the cutting height;
Setting status: change the parameter number and value
AUTO:
Stop work and auto work status: press it open the auto or close off the auto function. When stop status,
“AUTO” light is blink, means THC is allowed on auto status, if press “AUTO”, then the “AUTO” light is
off, then means the THC is on manual status.
Setting status: confirm the parameter setting(ENTER), will show “P” status on it.
IHS TEST
S
top work status: for IHS test
; press it, begin the IHS, after the IHS finished, automatically
recover, or press this button or “UP” button to recover it.
Other status: no valid
8 Function LED indictors:
UP/DOWN: Turn on when torch go up/ go down.
ARCON: Turn on when THC has detected the arc start signal. If arc start with IHS
enable, this indicator is off until IHS completed.
AUTO: Turn on means THC is on AUTO mode. 4 conditions must be satisfied:
1. Stop status, “AUTO” light is blink, means THC panel allows it at the AUTO status;
2. CNC send the arc start signal
;
3. CNC Auto Height Control(THC) enables;
4. THC finds the divided arc volt from CNC( Trans turns on); Actual Arc Voltage is
not higher than setting Arc Voltage over 30V.
TRANS
:
Turn on WHEN THC finds divided arc get into THC, and send out the pierce complete
signal to CNC.
IHS: Turn on when IHS.
UP_Limit
:
Turn on when torch go to up limit.
DN_Limit: Turn on when torch go to down limit.
Note: Only When at Stop status: press “up” and “down” button, then it can let the torch go up and
go down.
When ARC OK, press “MENU” to monitor the setting arc voltage, and if press “UP”or
“DOWN”, then to change the setting Arc Voltage or Sampling Arc Voltage. When at
stop status, it’s for set the parameters status.
When power on and setting parameter, some LED indictors will be blink according to the different