KN INSTALLATION INSTRUCTIONS FOR VENT AND AIR PIPING
4 Vent piped through a side wall
(combustion air from the boiler room)
KN-2
Vent components
Heat-Fab
KN-4
Vent components
Heat-Fab
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal
3-inch
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal
4-inch
Joint sealant, required
GE RTV106 or equivalent
Joint sealant, required
GE RTV106 or equivalent
Termination elbow
Termination pipe section
(1 ft)
Termination thimble
Gear clamp (nose clamp)
9314TERM
9302
9393S
3-inch clamp
Termination elbow
Termination pipe section
(1 ft)
Termination thimble
Gear clamp (nose clamp)
9414TERM
9402
9493S
4-inch clamp
See pages 15 – 18
5 Vent & air piped through a side wall
(separate vent and air terminations)
KN-2
Vent components
Heat-Fab
KN-4
Vent components
Heat-Fab
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal
3-inch
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal
4-inch
Termination elbow
Termination pipe section
(1 ft)
Termination thimble
Gear clamp (nose clamp)
9314TERM
9302
9393S
3-inch clamp
Termination elbow
Termination pipe section
(1 ft)
Termination thimble
Gear clamp (nose clamp)
9414TERM
9402
9493S
4-inch clamp
Joint sealant, required
GE RTV106 or equivalent
Joint sealant, required
GE RTV106 or equivalent
Air components
Heat-Fab
Air components
Heat-Fab
Termination elbow
Same as vent termination
Termination elbow
Same as vent termination
Air piping/components
(also supports, thimbles, etc.)
3-inch PVC, CPVC, ABS,
galvanized or aluminum
Air piping/components
(also supports, thimbles, etc.)
4-inch PVC, CPVC, ABS,
galvanized or aluminum
6 Vent & air piped through a side wall
(concentric vent/air termination)
KN-2
Vent components
Heat-Fab
KN-4
Vent components
Heat-Fab
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal, 3-inch piping
Saf-T Vent SC fi ttings for
termination assembly
Vent piping/components
(incl. supports, thimbles, etc.)
EZ-Seal, 4-inch piping
Saf-T Vent SC fi ttings for
termination assembly
Termination assembly:
• Single-wall adapter
• Air intake tee
• 6-inch straight section
• 12-inch straight section
• Wall plate (2 required)
• Termination adapter
• Mitered termination
SC03ADEZ
SC03TAD3
SC0366
SC03L12
SC03FS
SC03HT
9390
Termination assembly:
• Single-wall adapter
• Air intake tee
• 6-inch straight section
• 12-inch straight section
• Wall plate (2 required)
• Termination adapter
• Mitered termination
SC04ADEZ
SC04TAD3
SC0466
SC04L12
SC04FS
SC04HT
9490
Joint sealant, required
GE RTV106 or equivalent
Joint sealant, required
GE RTV106 or equivalent
Air components
Heat-Fab
Air components
Heat-Fab
Air piping/components
(also supports, thimbles, etc.)
3-inch PVC, CPVC, ABS,
galvanized or aluminum
Air piping/components
(also supports, thimbles, etc.
4-inch PVC, CPVC, ABS,
galvanized or aluminum
See pages 19 – 22
See pages 23 – 26
The Hydrotherm
KN
boiler — Vent and air piping options