Starting and stopping the control box
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
00h
xxh
00
00
00
00
00
00
Replace the xx in byte B1 with the desired command code:
0x01Start for ramp
0x02Stop for ramp
0x03Start for sine
0x04Stop for sine
Status of the heartbeat
The control box indicates its status via the heartbeat:
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
720
8
XXh
00
00
00
YY
YY
YY
YY
The following states are defined:
XX = 0x04 Device is stopped
XX = 0x05 Device is started
XX = 0x7F Control box in configuration mode
XX = 0x77 Control box in calibration mode
YY
Firmware version in ASCII format
Please use only spare parts and accessories from Hydrotechnik.
Product
Order no.
CAN cable - 5m
for connection to the MultiSystem 5060 Plus and MultiSystem 5070
8824-R7-05.00
CAN cable - 2,5m
for connection to existing CAN bus, e.g.
8824-N3-02.50
Power supply unit
8812-00-00.27
Temperature sensor
HySense TE 326, CAN, M12 5p m, 0…+150°C, G1/4 Form E
HySense TE 300, 4…20mA, M16 6p m, -50…+200°C, G1/4 Form E
3408-53C0-G213C01
3408-23C0-G231Z1S