18

CLEANING, DISINFECTING, AND ROUTINE MAINTENANCE PROCEDURE

CLEANING PROCEDURE

NOTE:

 

 Refer to individual System Assembly and Activation 

Procedures to identify specific components matching 

the descriptions shown in this procedure.

1. Disconnect system from electrical outlet.

2.  Mix a mild cleaning solution of dish soap and clean potable water 

in the plastic bucket.

3.  Close feed water supply valve and open downstream faucet to 

relieve system pressure.

CAUTION:

   Do not attempt to remove sumps until water flow 

stops. This reduces pressure inside the system so 

sumps may be safely removed.

NOTE:

  

For UVB and UV1 Models only:

 Remove and save 

Teflon Sleeve as it will be used again with replacement 

EPCB™ Carbon Filter.

4.  Remove each sump. Remove each filter as its sump is removed. 

Discard the filters. Use sump wrench to remove stubborn sumps.

NOTE:

 

 Use sanitary rubber gloves for this procedure to avoid 

contaminating cleaning solution or filters. Wear gloves 

whenever cleaning components or handling new 

filters.

5.  Clean quartz sleeve carefully using vinegar to remove hardness. 

Do not use abrasive materials. Rinse sleeve thoroughly with clean 

potable water. Replace any sleeve that is damaged or will not 

come completely clean.

6.  Remove sump “O” rings and wash with cleaning solution. Rinse 

them well with clean potable water. Inspect “O” rings for damage 

(i.e., nicks or scratches). Replace damaged “O” rings. 

CAUTION:

   Use care when cleaning UV head. Do not get the UV 

control module or connectors wet.

7.  Clean sumps and heads, inside and outside with washcloth and 

cleaning solution. Do not use abrasive materials. 

8. Rinse sumps and heads with clean potable water.

9.  

For UV20 Model only: 

Clean and rinse the Stainless Steel 

Channeling Sleeve (Item 3) and Sleeve Gasket (Item 4) shown in 

Figure 2.

10.  Inspect head and sump “O” ring groove area for damage (i.e., 

nicks or scratches). Replace damaged components.

11.  Place a small amount of silicone based “O” ring lubricant on 

the filter sump “O” ring. Install the “O” ring into the filter sump 

groove.

DISINFECTION PROCEDURE

CAUTION: 

   WEAR SAFETY GLASSES AND SANITARY RUBBER 

GLOVES WHILE PERFORMING THIS PROCEDURE.

CAUTION:

   EXCESSIVE CONCENTRATIONS OF BLEACH WILL 

DAMAGE PLASTIC AND RUBBER COMPONENTS. 

Rinse all parts that contact bleach thoroughly with 

clean potable water.

CAUTION:

   Read the “WARNINGS” on the bleach container before 

using.

CAUTION:

   Handle sanitizing solution carefully. Avoid contact with 

unprotected areas.

1. Disconnect system from electrical outlet.

2. Mix sanitizing solution: 

 

a.  

For UVB, UV1, and Addon Models only: 

 

Mix 59 ml (1/4 cup) of household bleach and 177 ml (3/4 

cup) of clean, potable water in the bucket. Mix the solution 

well. 

 

b  

For UV20 and UVBB Models only:  

 Mix 237 ml (1 cup) of household bleach and 237 ml (1 cup) 

of clean, potable water in the bucket. Mix the solution well.

CAUTION:

   Use care when sanitizing UV head. Do not get the UV 

control module or connectors wet.

CAUTION:

   TIGHTEN SUMPS BY HAND ONLY. Do not use tools 

as they will over-tighten and may damage sump. Take 

care not to cut or pinch “O” rings or gaskets. Use 

sump wrench for removal only.

3. Add sanitizing solution into system:

 

a.  

For UVB, UV1, and Addon Models only:  

Add 237 ml (1 cup) of sanitizing solution to the sump that 

contains the UV lamp.

 

b.  

For UV20 and UVBB Models only: 

 

Add 473 ml (2 cups) of sanitizing solution to the sump that 

contains the UV lamp.

RECOMMENDATIONS

HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE

A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR DISINFECT THE SYSTEM

(i.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)

EQUIPMENT NEEDED

Safety Glasses

Rubber Gloves, Sanitary

Wash Cloth, Clean and Lint-Free

Liquid Dish Soap

Household Bleach – Unscented Only

(5 ¼% Sodium Hypochlorite)

Plastic Bucket

“O” Ring Lubricant, Silicone Based

REPLACEMENT FILTERS

REPLACEMENT UV COMPONENTS

Refer to system Parts List for specific component part numbers.

Refer to system Parts List for specific component part numbers.

Содержание Aqua Flo ADDON Series

Страница 1: ...INSTALLATION MANUAL OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev 07 16...

Страница 2: ......

Страница 3: ...________________ 8 INSTALL ULTRAVIOLET LIGHT AND FILTERS______________________________________________ 8 9 ACTIVATE SYSTEM___________________________________________________________________ 9 SERVICE...

Страница 4: ...and create active sites where pollutants can be collected by adsorption These new sites dramatically increase the total surface area and capacity of each granule WHAT IS ADSORPTION Adsorption is the p...

Страница 5: ...quartz sleeve UV Lamp Replacement Lamps must be changed every twelve months While UV lamps rarely burn out they do lose their disinfection power Use only UV UV lamps as they are specifically designed...

Страница 6: ...V system to service the sumps and UV lamp without removing the UV system The minimum space is UVB 11 above and below UV20 UVBB 20 above and below UV1 10 above and below ADDON 10 or 20 above by model 4...

Страница 7: ...ing Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 Remove EPCB Carbon Filter Item 3 and EPCB Sleeve Item 24 from sump and set aside 6 For UVB2 and UVB3 Models only Remove S...

Страница 8: ...outlet If the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 9 above It is norma...

Страница 9: ...2800031 15 O Ring Quartz Sleeve Standard 34202021 16 Lamp UV 11 36002017 17 Sleeve Quartz 11 w O Rings 36003034 18 Rod Safety Plunger 22401015 19 Spacer Bushing 10 20 22401016 20 Head Filter 3 4 10 20...

Страница 10: ...tion 4 Insert quartz sleeve into the UV head As quartz sleeve passes the O Ring Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 For UV20 2 and UV20 3 Models only Remove Sump...

Страница 11: ...the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 8 above It is normal for the...

Страница 12: ...1 14 Washer 14 Nylon 32800031 15 O Ring Quartz Sleeve Standard 34202021 16 Lamp UV 20 36002018 17 Sleeve Quartz 20 with O Rings 36003035 18 Rod Safety Plunger 22401015 19 Spacer Bushing 10 20 22401016...

Страница 13: ...from quartz sleeve NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 6 For UVBB 2 and UVBB 3 Models only Remove Sump Item 1 from Filter Head Item 20 Remove F...

Страница 14: ...When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now...

Страница 15: ...trol BB 44302403 11 Screw 6 32 x 3 8 32701063 12 Screw 14 x 1 32701060 13 Screw 5 16 x 1 1 4 32701074 14 Washer 5 16 32800029 15 O Ring Quartz Sleeve BB 34202022 16 Lamp UV 20 36002018 17 Sleeve Quart...

Страница 16: ...6 nuts securing corner braces INSTALL UV SYSTEM TO RACK NOTE Items in this section refer to Figure 5 NOTE Figures 5 and 6 provide examples of configurations that may be applied to your UV system These...

Страница 17: ...stem Configuration and Component Parts Initial Installation DATE INSTALLED SYSTEM OUTPUT RATING LPM GPM CONFIGURATION SERIES SERIES TO PARALLEL PARALLEL PARALLEL TO SERIES MODULE 1 TYPE UV PART NUMBER...

Страница 18: ...r pin socket that is connected to the UV Control Item 11 8 Carefully insert the UV lamp through mounting bracket into the quartz sleeve as far as possible NOTE End of UV lamp will touch bottom of quar...

Страница 19: ...rol with Finish Cap 40200080 12 Bushing Spacer 10 SL 22401017 13 Cap Finish c w Control 14 Sleeve Quartz 10 with O Rings 36003033 15 Sleeve Teflon 30120506 16 O Ring Quartz Sleeve UV1 34202020 17 Lamp...

Страница 20: ...they will over tighten and may damage sump Take care not to cut or pinch Addon Sump Gasket Item 2 1 For ADDON 1GPM Model Only Remove Collar Item 15 from UV Head Item 5 NOTE Wipe all fingerprints and...

Страница 21: ...f UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks If there are leakages in the quick connect fittings check for the O ring pl...

Страница 22: ...p 40200080 11 Retainer O Ring Cap Finish c w Control 22401012 12 Sleeve Quartz 10 with O Rings 13 Sleeve Quartz 11 with O Rings 36003034 13A Sleeve Quartz 20 with O Rings 36003035 14 Tube Delivery 1gp...

Страница 23: ...nents 11 Place a small amount of silicone based O ring lubricant on the filter sump O ring Install the O ring into the filter sump groove DISINFECTION PROCEDURE CAUTION WEAR SAFETY GLASSES AND SANITAR...

Страница 24: ...V head Do not get the UV control module or connectors wet 3 Remove sump from UV head and set aside CAUTION Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiven...

Страница 25: ...packet on the outside of the open end of the quartz sleeve only on the area that will engage with the O ring CAUTION Apply even pressure to push the quartz sleeve into the UV head To avoid breakage m...

Страница 26: ...VE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a p...

Отзывы: