background image

7  

Sizing Requirements 

Water Pressure

 

The  water  system  must  have  a  pump  big  enough  to  deliver  the  recommended  backwash 
rate with a minimum pressure at the inlet of the filter of 30 psi. If the existing system can-
not do this, it must be upgraded to do so. Whenever possible, the water system should be 
adjusted to deliver at least 30 psi for even more satisfactory results. 

Backwash Flow Rates

 

The  most  important  criteria  in  sizing  a  filter  is  the  capacity  of  the  pump.  The  water  must 
pass through the filter media at the proper service flow rate.  The filter must also be back-
washed  at  a  flow  rate  sufficient  to  dislodge  and  remove  the  captured  particles.    Failure  to 
provide  sufficient  water  will  cause  a  build-up  of  particles  in  the  filter  media,  impairing  its  
ability. In order for your filter to backwash and rinse properly, your pump must be capable 
of providing the backwash flow rates indicated on page 4. 

Check Your Pumping Rate

 

Two water system conditions must be checked carefully to avoid unsatisfactory operation or 
equipment damage: 
 
1. 

Minimum water pressure required at the filter tank inlet is 20 psi. 

2. 

Measuring the pumping rate of your pump: 

 
With the pressure tank full, draw water into a container of known volume, and measure the 
number of gallons drawn until the pump starts again. This is draw-down. Divide this figure 
by cycle time and multiply the result by 60 to arrive at the pumping rate in gallons per min-
ute (gpm). To aid in your calculation, insert the date in the following formula: 
 
DRAW-DOWN  ______  ÷  CYCLE  TIME  _______  x  60  =  PUMPING  RATE  ________  (gals) 
(secs.) (Gpm) 
 
EXAMPLE:  

CYCLE  TIME  is  53  seconds.    DRAW-DOWN  is  6  gallons;  then,  PUMPING 

RATE equals: 
 

6 gallons ÷ 53 seconds x 60 = 6.8 gpm 

 

See chart on page 4 for minimum flow rates. 

 
NOTE:  

If  your  pumping  rate  is  inadequate  for  the  model,  do  not  install  your  filter  until 

the problem has been corrected. 
 

Содержание 89BM-100

Страница 1: ...rovided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Canadian Head Office 655 Park St Regina SK S4N 5N1 U S Head Office 8437 10th Avenue North Golden Valley MN 55427 IMPORTANT PLEASE REFER TO THE PICTURE BELOW ON INLET OUTLET SIDE...

Страница 2: ...manual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping cartons Contact the transportation company for all damage and loss claims The manufacturer is not responsible for damages in transit Small parts needed to install the softener are in a parts bag To ...

Страница 3: ... Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pressure may exceed the maximum Use a pressure ...

Страница 4: ...2 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Service Flow Rates Normal 2 0 gpm 3 0 gpm 5 0 gpm 6 0 gpm 7 0 gpm Peak 3 5 gpm 5 0 gpm 8 0 gpm 10 0 gpm 12 0 gpm Backwash Flow Rate 3 5 gpm 4 0 gpm 5 0 gpm 7 0 gpm 10 0 gpm Filter Media Volume Cubic Feet 0 75 ft 3 1 0 ft 3 1 5 ft 3 2 0 ft 3 3 0 ft 3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Ta...

Страница 5: ...days Before Starting Installation Tools Pipe and Fittings Other Materials Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modifi cation to home plumbing is required Plastic inlet and outlet fittings are included with the filter To maintain full valve flow 3 4 or 1 pipes to and from the filter fit tings are recommended You should main tain the ...

Страница 6: ...y Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the filter The transformer has an attached 6 foot power cable Be sure the electric outlet and transformer are in an inside location to protect from wet weather If i...

Страница 7: ...r pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage 1 Minimum water pressure required at the filter tank inlet is 20 psi 2 Measuring the pumping rate of your pump With the pressure tank full draw water into a container of known volume and m...

Страница 8: ...s when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This can be ran up overhead or down along the floor If running the drain line more than 20 ft overhead it is recommended to increase th...

Страница 9: ...9 Filter Installation ...

Страница 10: ...er to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on the water quality after which taste and odor problems may return When this happens contact your dealer for a replacement media bed MM Sediment and Turbidity Filter under normal operating conditions the...

Страница 11: ... 2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank and on to the distributor tube Tighten the control valve on to the tank Connect or reconnect the inlet and outlet and drain The control valve should be in the backwash position Slowly open the inlet v...

Страница 12: ...ws the Flow Rate Date Time Of Day Remaining Volume and Total Volume The display will alternate between the main page and the dealer information page PROGRAM LEVEL USER ACCESS MAIN MENU II These settings are programmed when the unit is installed The settings should only be adjusted by a quali fied person ADVANCED MENU II These settings are programmed by the factory and should be adjusted when the v...

Страница 13: ...ME Time of day is for normal operation of system and the scheduling of the regeneration time The date is used in a diagnostic function to track the last time the sys tem regenerated HARDNESS This value is the maximum compensated water hard ness in grains per gallon of the raw water supply It is used to calculate the system capacity If Ferrous Iron is present add 4 gpg for every 1 ppm of Ferrous Ir...

Страница 14: ...alve backwash brine slow rinse fast rinse service refill The regeneration steps of UP FLOW valve brine slow rinse backwash fast rinse service refill Set the Down Flow valve as an example when the valve get into backwash the screen will display Press any key will stop brine slow rinse and the valve will advance to the next regenera tion process Fast Rinse the screen will display ...

Страница 15: ...pen this state of operation is Service Rotate each of the two knobs in clockwise and anticlockwise respectively when the knobs on the bypass is in one line the inlet and outlet are both closed this state of operation is By pass The two small quick connector at the two sides are the sample connection for inlet and out let choose the right elbow connector for taking water samples ...

Страница 16: ... No Part description Qty No Part description Qty 1 Big O ring of Adaptor coupling 2 6 89 secure clip 2 2 Adaptor coupling of 89 control valve 2 7 89 valve connector 1 3 Small O ring of adaptor coupling 2 8 Connector O ring 2 9 1 0 6 3 2 1 4 5 7 8 ...

Страница 17: ...C assembly optional 1S 2S 3S 4S 1 3 4 5 6 1 4 Drain elbow O ring 1 5 Drain elbow 1 2 3 4 1 6 Brine valve injector stem assembly 1 7 Spacer and seal assembly 1 8 Three options of piston Down flow piston Up flow piston Filter piston 1 5 4 3 1 2 12 14 13 11 9 7 10 8 6 15 16 17 18 19 26 20 21 23 22 25 24 27 ...

Страница 18: ...Brine line adaptor assem bly optional BLFC 0 7gpm BLFC 0 95gpm 1 16 Injector assembly optional grey purple red white blue yellow 1 17 Injector cover O ring 1 18 Injector cover 1 19 Injector cover screws 2 20 Tank mouth O ring 1 21 Adapter O ring 1 22 Center pipe adapter 1 23 Center pipe O ring 1 24 Valve bottom connector 1 25 Bottom connector screws 2 26 Brass nuts 1 27 Brine line elbow assembly 1...

Страница 19: ...tions described in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation or operation contrary to our printed instructions damage to ion exchange resin and seals caused by chlorine chloramines in the water supply or dam age caused by any force of nature is not covered in...