background image

4  

Specifications 

• 

Continuous operation at flow rates greater than the ser-
vice  flow  rate  may  affect  capacity  and  efficiency  per-
formance. 

• 

The  manufacturer  reserves  the  right  to  make  product 
improvements which may deviate from the specifications 
and  descriptions  stated  herein,  without  obligation  to 

change previously manufactured products or to note the 
change. 

• 

Peak  flow  rates  are  intended  for  intermittent  use  only 
and are for residential application only 

• 

At  the  stated  service  flow  rates,  the  pressure  drop 
through these devices will not exceed 15 psig 

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

          Peak

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

15.0 gpm

Micron Rating

15-20 micron

15-20 micron

15-20 micron

15-20 micron

15-20 micron

Backwash Flow Rate

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

14.0 gpm

Filter Media Volume - Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

79 lbs

118 lbs

144 lbs

198 lbs

342 lbs

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

7.0 gpm

10 gpm

12.0 gpm

          Peak

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

15.0 gpm

Backwash Flow Rate

3.5 gpm

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

Filter Media Volume - Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

50 lbs

60 lbs

78 lbs

95 lbs

138 lbs

Service Flow Rates
          Normal

2.0 gpm

3.0 gpm

5.0 gpm

6.0 gpm

7.0 gpm

          Peak

3.5 gpm

5.0 gpm

8.0 gpm

10.0 gpm

12.0 gpm

Backwash Flow Rate

3.5 gpm

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

Filter Media Volume - Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

93 lbs

120 lbs

164 lbs

207 lbs

330 lbs

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

8.0 gpm

10.0 gpm

          Peak

7.0 gpm

8.0 gpm

10.0 gpm

12 gpm

Micron Rating

3-5 micron

3-5 micron

3-5 micron

3-5 micron

Backwash Flow Rate

5.0 gpm

7.0 gpm

10.0 gpm

14.0 gpm

Filter Media Volume - Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

Tank Jacket

Yes

Yes

Yes

No

Shipping Weight

90 lbs

135 lbs

205 lbs

255 lbs

ALL FILTERS
Plumbing Connections
Electrical Requirements
Water Temperature
Water Pressure

3/4" (Optional 1")

Input 120V 60 Hz - Output 12V 650mA

Min 39  - Max. 100 degrees Fahrenheit

Min. 20 - Max. 125 psi

48NEX-75

585NEX-100

585NEX-150

585NEX-200

485NU-75

585NU-100

585NU-150

585NU-200

585NU-300

585TO-75

585TO-100

585TO-150

585TO-200

585TO-300

585MM-75

585MM-100

585MM-150

585MM-200

585MM-300

Specifications

Specifications

Specifications

Specifications

89BM-75           89BM-100           89BM-150         89BM-200          89BM-300 

785TO-75           785TO-100        785TO-150        785TO-200         785TO-300 

785NU75           785NU-100        785NU-150        785NU-200         785NU-300 

785NEX75         785NEX-100       785NEX-150     785NEX-200         
785NU-300 

 

Содержание 89BM-100

Страница 1: ...rovided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Canadian Head Office 655 Park St Regina SK S4N 5N1 U S Head Office 8437 10th Avenue North Golden Valley MN 55427 IMPORTANT PLEASE REFER TO THE PICTURE BELOW ON INLET OUTLET SIDE...

Страница 2: ...manual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping cartons Contact the transportation company for all damage and loss claims The manufacturer is not responsible for damages in transit Small parts needed to install the softener are in a parts bag To ...

Страница 3: ... Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pressure may exceed the maximum Use a pressure ...

Страница 4: ...2 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Service Flow Rates Normal 2 0 gpm 3 0 gpm 5 0 gpm 6 0 gpm 7 0 gpm Peak 3 5 gpm 5 0 gpm 8 0 gpm 10 0 gpm 12 0 gpm Backwash Flow Rate 3 5 gpm 4 0 gpm 5 0 gpm 7 0 gpm 10 0 gpm Filter Media Volume Cubic Feet 0 75 ft 3 1 0 ft 3 1 5 ft 3 2 0 ft 3 3 0 ft 3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Ta...

Страница 5: ...days Before Starting Installation Tools Pipe and Fittings Other Materials Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modifi cation to home plumbing is required Plastic inlet and outlet fittings are included with the filter To maintain full valve flow 3 4 or 1 pipes to and from the filter fit tings are recommended You should main tain the ...

Страница 6: ...y Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the filter The transformer has an attached 6 foot power cable Be sure the electric outlet and transformer are in an inside location to protect from wet weather If i...

Страница 7: ...r pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage 1 Minimum water pressure required at the filter tank inlet is 20 psi 2 Measuring the pumping rate of your pump With the pressure tank full draw water into a container of known volume and m...

Страница 8: ...s when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This can be ran up overhead or down along the floor If running the drain line more than 20 ft overhead it is recommended to increase th...

Страница 9: ...9 Filter Installation ...

Страница 10: ...er to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on the water quality after which taste and odor problems may return When this happens contact your dealer for a replacement media bed MM Sediment and Turbidity Filter under normal operating conditions the...

Страница 11: ... 2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank and on to the distributor tube Tighten the control valve on to the tank Connect or reconnect the inlet and outlet and drain The control valve should be in the backwash position Slowly open the inlet v...

Страница 12: ...ws the Flow Rate Date Time Of Day Remaining Volume and Total Volume The display will alternate between the main page and the dealer information page PROGRAM LEVEL USER ACCESS MAIN MENU II These settings are programmed when the unit is installed The settings should only be adjusted by a quali fied person ADVANCED MENU II These settings are programmed by the factory and should be adjusted when the v...

Страница 13: ...ME Time of day is for normal operation of system and the scheduling of the regeneration time The date is used in a diagnostic function to track the last time the sys tem regenerated HARDNESS This value is the maximum compensated water hard ness in grains per gallon of the raw water supply It is used to calculate the system capacity If Ferrous Iron is present add 4 gpg for every 1 ppm of Ferrous Ir...

Страница 14: ...alve backwash brine slow rinse fast rinse service refill The regeneration steps of UP FLOW valve brine slow rinse backwash fast rinse service refill Set the Down Flow valve as an example when the valve get into backwash the screen will display Press any key will stop brine slow rinse and the valve will advance to the next regenera tion process Fast Rinse the screen will display ...

Страница 15: ...pen this state of operation is Service Rotate each of the two knobs in clockwise and anticlockwise respectively when the knobs on the bypass is in one line the inlet and outlet are both closed this state of operation is By pass The two small quick connector at the two sides are the sample connection for inlet and out let choose the right elbow connector for taking water samples ...

Страница 16: ... No Part description Qty No Part description Qty 1 Big O ring of Adaptor coupling 2 6 89 secure clip 2 2 Adaptor coupling of 89 control valve 2 7 89 valve connector 1 3 Small O ring of adaptor coupling 2 8 Connector O ring 2 9 1 0 6 3 2 1 4 5 7 8 ...

Страница 17: ...C assembly optional 1S 2S 3S 4S 1 3 4 5 6 1 4 Drain elbow O ring 1 5 Drain elbow 1 2 3 4 1 6 Brine valve injector stem assembly 1 7 Spacer and seal assembly 1 8 Three options of piston Down flow piston Up flow piston Filter piston 1 5 4 3 1 2 12 14 13 11 9 7 10 8 6 15 16 17 18 19 26 20 21 23 22 25 24 27 ...

Страница 18: ...Brine line adaptor assem bly optional BLFC 0 7gpm BLFC 0 95gpm 1 16 Injector assembly optional grey purple red white blue yellow 1 17 Injector cover O ring 1 18 Injector cover 1 19 Injector cover screws 2 20 Tank mouth O ring 1 21 Adapter O ring 1 22 Center pipe adapter 1 23 Center pipe O ring 1 24 Valve bottom connector 1 25 Bottom connector screws 2 26 Brass nuts 1 27 Brine line elbow assembly 1...

Страница 19: ...tions described in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation or operation contrary to our printed instructions damage to ion exchange resin and seals caused by chlorine chloramines in the water supply or dam age caused by any force of nature is not covered in...

Отзывы: