ECO-5 / 6100    Error Messages 

 

 

Pressure or Flow Switch Activated 

 

If 3 flashing dots appear below the temperature display, the printed circuit board must be checked to see if the LED 
error indicator is illuminated. If it 

is not

 the 3 flashing dots are related to a problem with the pressure or flow switch. If 

the system detects any pressure while the pump is turned off, 3 flashing dots will appear below the temperature 
display.

 

 

Power can remain On while the following steps are performed.

 

 

 

· 

Disconnect the pressure or flow switch 
cable from the printed circuit board.  

· 

If the 3 flashing dots do not go away, 
replace printed circuit. 

· 

Note: If the 3 flashing dots appear on 
the while the pump is operating, adjust 
or replace the pressure or flow switch. 

 

 

Pressure Switch 
Adjustment 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Important Test 
 

· 

Fill spa to maximum water level. 

· 

Apply power and operate jets on high 
speed to establish full water flow 
throughout the system. 

· 

Turn 

OFF

 all power to the system. 

· 

Remove the wires from the pressure 
switch. Place an Ohmmeter across both 
terminals to verify that the circuit is 
“open”. 

· 

Rotate the pressure switch adjustment 
screw 

counter-clockwise

 until the 

ohmmeter indicates a “closed” circuit. 

· 

Rotate the pressure switch adjustment 
screw 

clockwise

 until the ohmmeter just 

indicates an “open” circuit.  

· 

Replace wires on pressure switch, 
apply power and operate spa as 
normal. 

 

· 

Press and hold the Up Arrow Key to 
turn on the low speed pump and heater, 
unplug the pump cord to simulate a 
pump failure.  

· 

The heater should turn off and the 3 
flashing dots should appear on the 
spaside control display. 

· 

Warning - If the heater remains on, 
quickly plug the pump back in and 
repeat the above steps

 
 
 

 

 
 
 
 
 
 
 

  

 

 

 

 

 

Содержание Baja Sportub ECO-5/6100 Series

Страница 1: ......

Страница 2: ...1...

Страница 3: ...uired Parts Required Error Messages FLO Message FLC Message Prr Message HL Message Programming Low Level Programming Identified Problems Nothing Works Spa Is Not Heating Pump Does Not Work Ozonator Do...

Страница 4: ...cable Multi meter and clamp on Ammeter Accurate thermometer GFCI tester optional Parts Required Spaside control Temperature sensor Hi Limit sensor 30A Fuse System Board Pre Test Prior to the service c...

Страница 5: ...switch A system with a pressure switch displaying the pressure or flow switch not activated message will not be corrected by replacing the pressure switch Verify that the pump is working If the pump i...

Страница 6: ...r flow switch Pressure Switch Adjustment Important Test Fill spa to maximum water level Apply power and operate jets on high speed to establish full water flow throughout the system Turn OFF all power...

Страница 7: ...e the probe in the spa water If this solved the problem replace the sensor Replace the printed circuit board if the problem has not been corrected ECO 5 6100 Error Messages High Limit Sensor Over Heat...

Страница 8: ...f Open the access panel on the control box With a voltmeter read the voltage between P10 and P17 on the printed circuit board This is the power supply for the heater relay coil If you do not read 120...

Страница 9: ...mming Low Level Programming It is possible to change the parameters of the Equipment System by positioning specific jumpers located on the system board Jumper 1 Position 1 High Current 240vac There is...

Страница 10: ...the Line 1 fuse is good If you are getting good voltage readings but nothing seems to work verify that the Spaside control is properly connected to the system circuit board and external receptacle if...

Страница 11: ...heating replace the printed circuit board If the Heater On indicator does illuminate Open the access panel on the control box and measure the voltage between P10 and P17 at the system circuit board Re...

Страница 12: ...he keypad is not defective If the keypad is defective replace the spaside control If the keypad is not defective replace the printed circuit board Pump Indicator does illuminate If the Pump indicator...

Страница 13: ...es not work perform the following tests to correct the problem It is important to measure voltage when the light is connected to the System Power must remain on The first step is to replace the bulb o...

Страница 14: ...the following tests to correct the problem Make sure the Programming Jumpers are set properly Refer to Programming Replace spaside control with a spare Check to see if the keys are responding If they...

Отзывы: