![Hydronix Hydro-Probe XT Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/hydronix/hydro-probe-xt/hydro-probe-xt_user-manual_2192332054.webp)
54 Hydro-Probe XT User Guide HD0538 Rev: 1.6.0
1.2
Symptom: Incorrect analogue output
Possible
explanation
Check
Required result
Action required on
failure
Wiring problem
Wiring at the
junction box and
PLC
Twisted pairs used
for complete length
of cable from sensor
to PLC, wired in
correctly
Wire correctly using
specified cable in
the technical
specification
Sensor’s analogue
output is faulty
Disconnect the
analogue output
from the PLC and
measure with an
ammeter
Milliamp reading
within the normal
range (0-20mA, 4-
20mA)
Connect sensor to a
PC and run Hydro-
Com. Check
analogue output on
the diagnostics
page. Force the
mA output to known
value and check
this with an
ammeter
PLC analogue input
card is faulty
Disconnect the
analogue output
from the PLC and
measure the
analogue output
from the sensor
using an ammeter
Milliamp reading
within the normal
range (0-20mA, 4-
20mA)
Replace analogue
input card
1.3
Symptom: Computer does not communicate with the sensor
Possible
explanation
Check
Required result
Action required on
failure
No power to sensor DC power at
junction box
+15Vdc to +30Vdc
Locate fault in
power supply/ wiring
RS485 incorrectly
wired into converter
Converter’s wiring
instructions and A
and B signals are
the correct
orientation.
RS485 converter
correctly wired
Check PC Com port
settings
Incorrect serial Com
Port selected on
Hydro-Com
Com Port menu on
Hydro-Com. All
available Com
Ports are
highlighted on the
pull down menu
Switch to the correct
Com Port
More than one
sensor has the same
address number
Connect to each
sensor individually
Sensor is found at
an address.
Renumber this
sensor and repeat
for all the sensors
on the network
Try an alternative
RS485-RS232/USB
if available
Содержание Hydro-Probe XT
Страница 4: ...4 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 6: ...6 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 8: ...8 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 10: ...10 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 14: ...Chapter 1 Introduction 14 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 42: ...Chapter 4 Configuration 42 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 52: ...Chapter 6 Optimising Sensor and Process Performance 52 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 58: ...Chapter 7 Sensor diagnostics 58 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 60: ...Chapter 8 Technical specification 60 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Страница 66: ...Appendix B Document Cross Reference 66 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...