background image

– Your Authorized Local Distributor –

www.hydromatic.com

STANDARD LIMITED WARRANTY

 

 

 

 

 

HYDROMATIC

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - 

provided  that  such  products  are  used  compliance  with  the  requirements  of  the  Hydromatic  catalog  and          

technical  manuals  for  use  in  pumping  raw  sewage,  municipal  wastewater  or  similar,  abrasive  free                 

non-corrosive liquids. 

During the warranty period and subject to the conditions set forth, Hydromatic, at its discretion, will repair or 

replace  to  the  original  user,  the  parts  which  prove  defective  in  materials  and  workmanship.  Hydromatic 

reserves the right to change or improve its products or any portions thereof without being obligated to provide 

such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics

 may be required to support warranty claims. Warranty is 

effective only if Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be 

hooked up, functional and monitored or this warranty will be void. Hydromatic will only cover the lower seal 

and labor thereof for all dual seal pumps. Under no circumstance will Hydromatic be responsible for the cost 

of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from 

the factory or an authorized Hydromatic service facility.

This limited warranty will not apply:

 (a) to defects or malfunctions resulting from failure to properly 

install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting 

from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such 

service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good 

trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other 

than for what it is designed and manufactured; (g) to any unit which has been repaired or altered by anyone 

other than Hydromatic or an authorized Hydromatic service provider; (h) to any unit which has been repaired 

using non factory specified/OEM parts.

Warranty Exclusions:

 HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND 

BEYOND THE DESCRIPTION ON THE FACE HEREOF. HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability  Limitation:

  IN  NO  EVENT  SHALL  HYDROMATIC  BE  LIABLE  OR  RESPONSIBLE  FOR                    

CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER 

TO ANY HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE 

MAY  RESULT  FROM  IMPROPER  INSTALLATION.  HYDROMATIC  DISCLAIMS  ALL  LIABILITY,  INCLUDING   

LIABILITY  UNDER  THIS  WARRANTY,  FOR  IMPROPER  INSTALLATION.  HYDROMATIC  RECOMMENDS   

INSTALLATION BY PROFESSIONALS.

Some  states  do  not  permit  some  or  all  of  the  above  warranty  limitations  or  the  exclusion  or  limitation  of              

incidental  or  consequential  damages  and  therefore  such  limitations  may  not  apply  to  you.  No  warranties          

or  representations  at  any  time  made  by  any  representatives  of  Hydromatic  shall  vary  or  expand  the                 

provision hereof.

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

Item # E-03-359  04/09

Part # 5625-359-1

©2009 Hydromatic

®

  Ashland, Ohio.  All Rights Reserved.

Содержание PULTRUDED RAIL SYSTEM

Страница 1: ...To the installer Please make sure you provide this manual to the owner of the pumping equip ment or to the responsible party who maintains the system Part 5625 359 1 Item E 03 359 04 09 PULTRUDED RAIL SYSTEM ...

Страница 2: ...nge should release easily Step 2 Attach supplied chain leg to achieve a three point lift Test the balance of the pump by adjusting the location of the shackle in reference to individual chain links The pump must be level to function properly WARNING If the sealing flange end of pump is raised above the horizontal the guide rail may be damaged upon lowering the pump Ensure pump is horizontal before...

Страница 3: ...vertical discharge piping modules to elbow using bolts nuts lock washers and gasket NOTE When increasing the pipe size at the discharge elbow an eccentric flanged reducer coupling may be required to avoid interference with the guide rail See Installation Data Install remainder of the sump discharge piping This typically includes a vertical run of piping appropriately sized and configured to mate w...

Страница 4: ...ate Guide Rail Bracing Sump depths of 9 6 and greater require intermediate guide rail bracing The braces mount on the vertical discharge pipes with U bolts which are sized according to the discharge pipe size The number of guide rail braces required are as follows Sump Depths 9 6 to 18 0 1 guide rail brace required 18 6 to 27 0 2 guide rail braces required 27 6 to 30 0 3 guide rail braces required...

Страница 5: ... the pump or bottom of the basin Shorten cords to suit the installation See Bulletin Q 701 for the Installation and Service Manual on the electrical Control Panel system 11B Control Panel Mounted Remote from Basin If the Control Panel is remotely located instead of on the mounting stand at the basin install coupling through basin wall Screw protective bushing from inside basin into coupling all fu...

Страница 6: ...clogged Amperage higher than name plate will indicate this 2 Pump rotation may be wrong Reversing any two line leads on three phase pumps will reverse the rotation 3 Discharge plug valve may be closed 4 Plugging anywhere from impeller to sealing flange This is evident if no water runs out of sealing flange after raising the pump Pull the pump from the basin to find the clog 5 Plugging beyond the s...

Страница 7: ...LTRUDED RAIL I BEAM HYDRAULIC SEALING FLANGE ASSEMBLY WITH BUNA DIAPHRAGM right hand to suspend the float the pump should continue to run The pump should stop when raising the left hand to suspend the float If this procedure does not cause the pump to operate as described either order new 3900 mercury float switches or replace alternator relay PULTRUDED RAIL SYSTEM ...

Страница 8: ...XCEEDING 9 6 HYDROMATIC 3900 SUBMERSIBLE LEVEL SWITCHES HYDROMATIC NON CLOG SUBMERSIBLE PUMP HOPPER BOTTOM RECOMMENDED DISCH ELBOW FRP GUIDE RAIL LIFTING CHAIN VENT PIPING DEPTH OF WELL FT IN INFLUENT PIPE INV EL CONTROL POWER CABLES CONTROL CABLE MOUNTING BRACKET E G F SUMP SUMP SUMP MIN WATER LEVEL GRADE ELEV ELEV D C SIMPLEX 3 THROUGH 6 PUMPS ...

Страница 9: ... EXCEEDING 9 6 HYDROMATIC 3900 SUBMERSIBLE LEVEL SWITCHES HYDROMATIC NON CLOG SUBMERSIBLE PUMP HOPPER BOTTOM RECOMMENDED DISCH ELBOW FRP GUIDE RAIL LIFTING CHAIN VENT PIPING DEPTH OF WELL FT IN INFLUENT PIPE INV EL CONTROL POWER CABLES CONTROL CABLE MOUNTING BRACKET H F G E SUMP SUMP SUMP SUMP MIN WATER LEVEL GRADE ELEV ELEV DUPLEX 3 THROUGH 6 PUMPS ...

Страница 10: ...ons provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other than for what it is designed and man...

Страница 11: ......

Страница 12: ...___________________________ D Incoming line voltage _________________________ Actual _____________________________ E Voltage to pumps ____________________________ Actual _____________________________ F Type of junction box _____________________________ Manufacturer _______________________ G Are floats installed in wet well _______________________________________________________ H Are floats set to...

Отзывы: