1.0 INTRODUCTION

1.1 General Description

The Model 5033-XX Solar Panel provides battery charging at remote sites which have
power requirements that exceed battery capacity during the normal maintenance period.

1.2 Specifications 

Solar Panel

Maximum Power:

See Manufactures Specifications 

Open Circuit Voltage:
Short Circuit Current:
Voltage at Load:
Current at Load:

Voltage Regulator

Array Voc, Max:

26 Vdc

Voltage Drop:

0.55 Vdc

Charge Termination:

14.3 ±0.2 Vdc

Charge Resumption:

13.2 ±0.3 Vdc

Quiescent Current:

10 mA

Operating Temp.:

-20 to 50°C

Storage Temp.:

-55 to 85°C

2.0 INSTALLATION

2.1 Site Selection

When considering a solar site take panel alignment and shading into account. The panel
must face south (in the northern Hemisphere) and the panel must not be shaded between
9:00 A.M. to 3:00 P.M. (solar time).

2.2 Tilt Angle

To achieve maximum output the panel should be 

normal

(90°) to the sun; this is the

Tilt

Angle

and is measured above the horizontal. The Tilt Angle is difficult to maintain at

remote sites because the angle of the sun varies 47° through out the year. For year round
operation the tilt angle is optimized for the winter months when the solar energy will be the
lowest. The following table gives the tilt angle based on latitude of the site.

Содержание 5033-XX

Страница 1: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Instruction Manual Document No A102759 Document Revision Date December 2004...

Страница 2: ...e items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of th...

Страница 3: ...on 5 1 2 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 2 Tilt Angle 5 2 3 Installation 6 3 0 THEORY OF OPERATION 6 3 1 Solar Resource 6 3 2 Solar Panel 7 3 3 Voltage Regulator 7 3 4 Power...

Страница 4: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Page 4 A102759 Equipment Configuration and Parts Identification Model 5033 XX Solar Panel...

Страница 5: ...scent Current 10 mA Operating Temp 20 to 50 C Storage Temp 55 to 85 C 2 0 INSTALLATION 2 1 Site Selection When considering a solar site take panel alignment and shading into account The panel must fac...

Страница 6: ...mast pole or standpipe with hose clamps Thread power cable with 3 pin connector through standpipe cable port Install antenna mast onto the standpipe Align panel to face true south Tighten clamps Adjus...

Страница 7: ...temperature 1 kW m 25 C which allows for comparison of solar panel power ratings The NOC tests the panel performance in actual field conditions which allow designers a better estimate of true field p...

Страница 8: ...overcharged Test Fixture Switches SW1 V SW2 w oL SW3 no Volt meter is connected as shown in Figure 1 Limit Manufacture s specification 4 1 2 With Load Test Power watts Testing with a Load insures tha...

Страница 9: ...ense resistor and Volt meter to make this measurement Cover solar panel completely Press Pushbutton Switch SW 3 for measurement Limit 15 mA 4 2 Maintenance Inspect the module for overall integrity Che...

Страница 10: ......

Отзывы: