Model 5033-XX Solar Panel
HydroLynx Systems, Inc.
A102759
Page 5
1.0 INTRODUCTION
1.1 General Description
The Model 5033-XX Solar Panel provides battery charging at remote sites which have
power requirements that exceed battery capacity during the normal maintenance period.
1.2 Specifications
Solar Panel
Maximum Power:
See Manufactures Specifications
Open Circuit Voltage:
Short Circuit Current:
Voltage at Load:
Current at Load:
Voltage Regulator
Array Voc, Max:
26 Vdc
Voltage Drop:
0.55 Vdc
Charge Termination:
14.3 ±0.2 Vdc
Charge Resumption:
13.2 ±0.3 Vdc
Quiescent Current:
10 mA
Operating Temp.:
-20 to 50°C
Storage Temp.:
-55 to 85°C
2.0 INSTALLATION
2.1 Site Selection
When considering a solar site take panel alignment and shading into account. The panel
must face south (in the northern Hemisphere) and the panel must not be shaded between
9:00 A.M. to 3:00 P.M. (solar time).
2.2 Tilt Angle
To achieve maximum output the panel should be
normal
(90°) to the sun; this is the
Tilt
Angle
and is measured above the horizontal. The Tilt Angle is difficult to maintain at
remote sites because the angle of the sun varies 47° through out the year. For year round
operation the tilt angle is optimized for the winter months when the solar energy will be the
lowest. The following table gives the tilt angle based on latitude of the site.
Содержание 5033-XX
Страница 10: ......