Model 5033-XX Solar Panel
HydroLynx Systems, Inc.
A102759
Page 9
Figure 4
Reverse Dark Current
4.1.3 Reverse Dark Current Test
The panel should not draw current from the battery
during periods of non-operation i.e. at night. This test
verifies low Reverse Dark Current.
(Test Fixture Switches: SW1-A, SW2-w/oL, SW3-yes)
!
Battery and current meter are connected as shown
in Figure 4; the test fixture uses a 1 Ohm sense
resistor and Volt meter to make this measurement.
!
Cover solar panel completely.
!
Press Pushbutton Switch (SW-3) for measurement.
!
Limit: 15 mA.
4.2 Maintenance
Inspect the module for overall integrity.
Check that all connections are tight and free of corrosion.
When the panel becomes dirty use water and a soft cloth or synthetic sponge to clean the
glass surface. A mild, non-abrasive detergent can be used to remove persistent
contaminants. Avoid using brushes or abrasive cleansers.
Warning:
electrical shock can occur whenever the panel becomes wet! Wear rubber
gloves whenever cleaning the panel.