Do not install the unit where the source/inlet pressure may be more than 80 psi or there are
excessive water hammer/spike problems. If your inlet pressure is more than 80 psi, install
a 3/8” pressure regulator (
HL 10071
see pg. 15), available at your dealer or through
HydroLogic.
•
Keep out of direct sunlight or high intensity lights, which degrade the housing and fittings over
time. For added protection use the Algae Block Sleeve (
HL 26009
see pg. 15) to protect
from sun or lights.
•
When replacing filter cartridges, use the filter wrench to remove housings. Do not use the
wrench to tighten the housings.
Hand-tighten the housings only.
Take care not to over-tighten.
•
Do not install where leakage or failure may cause damage to property.
•
If you are going to store or not use your
stealth-RO
for an extended period of time (2
weeks+), remove your membranes, seal them in plastic and put in refrigerator.
•
Protect unit against freezing to prevent cracking of the filter housings and water leakage.
•
Replace both clear pre-filter housings every three years:
HL 23165
from your local dealer
or from HydroLogic.
•
Do not drop or place heavy objects on top of unit.
Description
HydroLogic
Part #
Product Water
Flow Rate
Inlet Tubing
Size
Product Tubing
Size
Waste
Tubing
Size
STEALTH-R0300
HL 31040
300 GPD (Gallons Per Day)
*
12.5 GPH (Gallons Per Hour)
3/8”
1/4”
1/4”
*
see pg. 18 for operating limits
PRECAUTIONS
REVERSE OSMOSIS MEMBRANE DIAGRAM
3