HydroHoist HarborHoist 12000 Скачать руководство пользователя страница 5

 

Rev A                                                                                            2003215 

Four Valve Control General Operation  

 

 

Familiarize yourself with the Control Box. We have created a simple to use 4 BUTTON user interface con-
sisting of UP, STOP, DOWN, and LEVEL buttons. These are the basic functions for operating the HarborHoist 
lift.  The state-of-the art valve controls and circuitry will insure that your lift comes up level each and every 
time you lift your boat from the water.  

 Lowering the lift:  

 

Make sure the Power LED is illuminated and flashing 

 

Press the 

DOWN

 button, this will open the valves 

 

Allow the lift to submerge (walkways will remain above water) 

 

Untie lift safety lines from boat 

 

Board the boat only after it clears the lift

 

Raising the lift: 

 

Make sure the Power LED is illuminated and flashing 

 

Float boat into established balanced lifting position on the lift 

 

Tie off safety lines to the boat 

 

Everyone must exit the boat before lifting 

 

Press 

UP

 button 

 

Once the lift is fully raised, air bubbles will be visible exiting from 

ALL 

main tanks 

 

Press 

STOP

 on control 

Re–level the lift: 

If for some reason the lift should become out of level while in the up position perform the following:  

 

Press the 

LEVEL

 

button.  This will open up the valves necessary and lower the high points of the lift to 

make it level.   The control will shut off once the lift is level.  You can then proceed with either lifting or 
lowering the lift as desired  

 

Note: 

you may want to check for leaks in the air system, this could be the cause of the lift becoming un-

level over time.

 

 

Содержание HarborHoist 12000

Страница 1: ...Rev A 2003215...

Страница 2: ...of the con trol Verify that your power receptacle is clean and is supplying between 110VAC 120VAC with at least 15 amps of service Keep children away Do not allow yourself to be distracted or walk aw...

Страница 3: ...uration 4400 6600 8800 4 Valve 8800 Short 12000 15000 18000 20000 5 Valve 25000 6 valve Control Configurations and Functionality 4 Valve Control Button Control A LEVEL Levels lift B UP Raises lift C S...

Страница 4: ...es lift C STOP Stops all operation of lift D Down Lowers lift LEDs A Front Port FP valve LED B Port P C Auxiliary AUX D Rear Port RP valve LED E Front Starboard FS valve LED F Starboard S G Rear Starb...

Страница 5: ...after it clears the lift Raising the lift Make sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyon...

Страница 6: ...ety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than 10 degrees the lift will go into Safety Shut Down Mode The PORT and STAR...

Страница 7: ...sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyone must exit the boat before lifting Press UP b...

Страница 8: ...only fill when the lift is within 2 degrees of level Safety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than 10 degrees the...

Страница 9: ...that has enough strength for the size of boat and lift you are installing Minimum Rope Dia of 3 8 for boats up to 25 1 2 for boats up to 35 and 5 8 for boats up to 45 There are several variables invol...

Страница 10: ...ntact the vessel manufacture for CB of your vessel To promote water drainage to the rear of the vessel it is recommended that the vessel CB be aft of the lift CB Some service vessels which are heavy a...

Страница 11: ...Rev A 2003215 CB of 6600 CB of 8800 CB of 8800 Short...

Страница 12: ...Rev A 2003215 CB of 12000 CB of 15000 CB of 18000...

Страница 13: ...Rev A 2003215 CB of 20000 CB of 25000...

Страница 14: ...essed see GFCI Test Pro cedure All air hoses are firmly attached clamps are tight and there are no apparent leaks All the aluminum components are structurally sound and no heavy corrosion is visible T...

Страница 15: ...r is removed Lift is not lifting the vessel level Re position the vessel on the lift Verify weight is distributed evenly in the vessel Verify ballast tanks bait or live wells do not have water remaini...

Страница 16: ...e in a fully up position before performing this operation Push and hold the UP and DOWN buttons at the same time until the PORT and STAR BOARD LED s flash together 5 times C Your level sensor is now r...

Страница 17: ...never be forward of the Center of the lift This condition suggests another set of Main tanks may be needed due to length if it is over by less than 18 the boat can be shifted back If the Auxiliary ta...

Страница 18: ...caused by disaster such as fire flood wind and lightning f Damage caused by unauthorized attachments or modification g Damage caused by operation maintenance or repair of the product contrary to writt...

Отзывы: