Troubleshooting  

Control will not power on 

 

Verify GFCI has not tripped  

 

Verify GFCI on dock receptible has not tripped. Verify dock power is  on 

 

Verify cable or power connection is not damaged  (unplug before inspection)  

 

Over time the lift lowers on its own  

 

Leaky air hose, tank or fitting  

 

While operating DO NOT unplug the control, doing so will allow the valves to remain open. 
When operating press 

STOP then 

wait 5 seconds before unplugging control. This will allow all 

valves time to close properly before power is removed 

 

Lift is not lifting the vessel level 

 

Re-position the vessel on the lift  

 

Verify weight is distributed evenly in the vessel   

 

Verify  ballast tanks, bait or live wells do not have water remaining in them 

 

Verify the lift raises level when vessel is not on the lift  

 

If lift is not level, verify sensor is connected to the frame properly and no damage has 
occurred to it or its cable  

 

The level sensor may need to be calibrated back to zero level (See 

Calibrating the level 

sensor to zero level 

on instructions)  

 

PORT  and STARBOARD LEDs will flash together rapidly on the control   

 

The level sensor has lost communication with  the control. Contact your local dealer or Har-
borHoist customer service support for assistance 

 

 

Содержание HarborHoist 12000

Страница 1: ...Rev A 2003215...

Страница 2: ...of the con trol Verify that your power receptacle is clean and is supplying between 110VAC 120VAC with at least 15 amps of service Keep children away Do not allow yourself to be distracted or walk aw...

Страница 3: ...uration 4400 6600 8800 4 Valve 8800 Short 12000 15000 18000 20000 5 Valve 25000 6 valve Control Configurations and Functionality 4 Valve Control Button Control A LEVEL Levels lift B UP Raises lift C S...

Страница 4: ...es lift C STOP Stops all operation of lift D Down Lowers lift LEDs A Front Port FP valve LED B Port P C Auxiliary AUX D Rear Port RP valve LED E Front Starboard FS valve LED F Starboard S G Rear Starb...

Страница 5: ...after it clears the lift Raising the lift Make sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyon...

Страница 6: ...ety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than 10 degrees the lift will go into Safety Shut Down Mode The PORT and STAR...

Страница 7: ...sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyone must exit the boat before lifting Press UP b...

Страница 8: ...only fill when the lift is within 2 degrees of level Safety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than 10 degrees the...

Страница 9: ...that has enough strength for the size of boat and lift you are installing Minimum Rope Dia of 3 8 for boats up to 25 1 2 for boats up to 35 and 5 8 for boats up to 45 There are several variables invol...

Страница 10: ...ntact the vessel manufacture for CB of your vessel To promote water drainage to the rear of the vessel it is recommended that the vessel CB be aft of the lift CB Some service vessels which are heavy a...

Страница 11: ...Rev A 2003215 CB of 6600 CB of 8800 CB of 8800 Short...

Страница 12: ...Rev A 2003215 CB of 12000 CB of 15000 CB of 18000...

Страница 13: ...Rev A 2003215 CB of 20000 CB of 25000...

Страница 14: ...essed see GFCI Test Pro cedure All air hoses are firmly attached clamps are tight and there are no apparent leaks All the aluminum components are structurally sound and no heavy corrosion is visible T...

Страница 15: ...r is removed Lift is not lifting the vessel level Re position the vessel on the lift Verify weight is distributed evenly in the vessel Verify ballast tanks bait or live wells do not have water remaini...

Страница 16: ...e in a fully up position before performing this operation Push and hold the UP and DOWN buttons at the same time until the PORT and STAR BOARD LED s flash together 5 times C Your level sensor is now r...

Страница 17: ...never be forward of the Center of the lift This condition suggests another set of Main tanks may be needed due to length if it is over by less than 18 the boat can be shifted back If the Auxiliary ta...

Страница 18: ...caused by disaster such as fire flood wind and lightning f Damage caused by unauthorized attachments or modification g Damage caused by operation maintenance or repair of the product contrary to writt...

Отзывы: