12
2.OO installation
(continued)
2.O4 Electrical Installation
(continued)
Rinse Pumps - Signal Wiring and Programming
(continued)
Model R1S - Dish Machine with Two Solenoids
Connect the signal cable to the solenoid valve for the rinse water.
Speed Setting
The pump runs at the speed set using the left potentiometer.
•
Minimum speed (completely turned counterclockwise): 10%
•
Maximum speed (completely turned clockwise): 100%
The speed setting is also indicated by flashing the green LED, proportional
to the set speed. For example:
10% = 5 seconds ON / 5 seconds OFF = one flash per 10 seconds
50% = 1 second ON / 1 second OFF = five flashes per 10 seconds
100% = 0.5 second ON / 0.5 second OFF = ten flashes per 10 second
The LED of a model R1S can display three colors to indicate the various pump operation phases:
Rinse Pump Speed
Potentiometer
10% to 100%
Model R1S: Pump Speed Potentiometer
10%
100%
LED
LED Color
Fixed or Flashing
Indication
Green
Fixed
You should not see the LED display as fixed green. (If you do see the LED display as fixed
green, please contact Technical Support at Hydro Systems Co.)
Flashing
Flashing green indicates the pump is dosing the, and the frequency of the flashing is
proportional to the user-defined pump speed.
Orange
Fixed
Fixed orange means the pump is in Priming Mode.
Flashing
You should not see the LED display as flashing orange. (If you do see the LED flashing orange,
please contact Technical Support at Hydro Systems Co.)
Red
Fixed
Fixed red could indicate the signal is active, but the pump switch is on the standby/OFF
position.
Fixed red could also indicate that the pump has jammed while the signal is active and the
switch is in the ON position
Flashing
You should not see the LED display as flashing red. (If you do see the LED flashing red,
please contact Technical Support at Hydro Systems Co.)