Power Pack and Components
Gas-powered unit
Emergency
stop button
Choke button
Startup button
Throttle lever
1-
Prepare the motorized unit and the engine by following the startup preparation
instructions on p. 69.
2-
Pull out the emergency stop button (fi g. 4.10) to power on the display screen. If the
display screen does not turn on after a short period of time, make sure the battery is
plugged in and that it has enough voltage. If the display screen still does not turn on,
call a qualifi ed technician. For the defi nition of a qualifi ed technician, refer to p. 7
of the
Performance and Safety Rules
section.
Motorized unit startup procedure
3-
Once powered on, unlock the
display screen as described in the
instructions on p. 76 of the
Control
Panel
section.
4-
Lower the throttle control lever at 3/4
of the way (fi g. 4.10).
5-
If the engine is cold, push and hold
the choke button.
6-
Push and hold the start button to
crank the engine until it starts (hold
for no more than 10 seconds at a
time).
7-
Release the choke button once the engine has started. In cold weather, hold the choke
button a little longer.
8-
Lower the throttle control lever all the way down to reach maximum
RPM
. In cold
weather, let the engine run at full throttle for a few minutes to warm up the hydraulic
system. If the unit is equipped with a hydraulic oil heater/recirculator, refer to p. 129
of the
Accessories
section for instructions.
9-
On model F300 or in a confi guration using more than one motorized unit, repeat steps
1 through 8. In a linked confi guration using model F300 it is mandatory to start both
engines.
10-
If the motorized unit is used in a multiple unit confi guration, make sure that the
inclinometer has been connected into the control panel and that the inclinometer option
has been enabled on the display screen. For instructions on enabling options on the
display screen, refer to p. 82 of the
Control Panel
section.
1-
Bring the motorized unit to the desired work level or down to base level.
2-
If the motorized unit was used in a multiple unit confi guration, make sure that no slope
alert is displayed on the display screen and that the structure is level.
3-
Push the throttle control lever all the way up (idle position) and let the engine run at
idle for 1 minute.
4-
In order to avoid unauthorized operation of the motorized unit, perform the following
steps to lock the control panel:
a.
Return to the main menu on the display screen
b.
Press
twice
on the
OK
button under the display screen to reach the access code
entry screen
c.
Press on one of the bottom left buttons to log out of the screen
5-
Push in the emergency stop button to shut down the engine and turn off the control panel.
Engine shutdown procedure
NOTE
If the motorized unit is used in cold weather, it is recommended to install and
use the optional hydraulic oil heater/recirculator.