Vacuum Connections
The MX3-200HE has a unique vacuum system which allows you to
connect your vacuums in either parallel or in series. Vacuum
connections can be changed quickly, with only a screw driver.
∗
THIS MUST BE PERFORMED BY A QUALIFIED
TECHNICIAN
While there is debate on which vacuum alignment provides the best
extraction, this much is true:
•
Two vacuums in series: The vacuum lift is increased by 1.6 times
the rating of a single vacuum, while the air flow stays the same as
a single vacuum.
•
Two vacuums in parallel: The vacuum air flow is increased by
2.0 times the rating of a single vacuum, while the lift says the same.
Air flow is usually measured in cubic feet per minute, indicated as CFM.
Lift is usually measured in inches of water column, indicated as “H2O or “WC.
To connect vacuums in parallel:
1.
Connect the discharge / exhaust hose from vacuum #1 to the exhaust
pipe on machine base.
2.
Place the rubber stopper into the vacuum inlet port of vacuum
manifold number two.
3.
Open vacuum gate valve and attach the Gatekeeper to prevent
accidental valve closure.
When connected in parallel, both vacuums must be running during
cleaning. Vacuums cannot be operated individually.
To connect vacuums in series:
1.
Connect the discharge / exhaust hose from vacuum #1 to the
vacuum inlet port of vacuum manifold number two.
2.
Place rubber stopper into the exhaust pipe on machine base.
3.
Remove Gatekeeper and close vacuum gate valve.
When connected in series vacuums can be operated individually if desired during cleaning.
Always secure the Gate Valve Open with the
Gatekeeper when connecting the vacuums in Parallel. Closing
the Vacuum Gate Valve with the hoses connected in the
Parallel configuration may cause damage to Vacuum
#2.
Section
2
GATEKEEPER
Содержание Nautilus MX3-200HE
Страница 1: ...1 LMANN09 Revised 02 16 2018 Nautilus MX3 200HE Operating Manual ...
Страница 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Страница 39: ...39 1 2 6 7 8 9 11 3 8 9 12 4 4 3 10 5 15A 8 9 8 9 39 2 ...
Страница 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 52 VACUUM MOUNTS CONNECTIONS 9 54 64 ...
Страница 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 103 ...
Страница 49: ...49 FLOW 81 92 91 99 96 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 103 39 9 ...
Страница 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 98 111 ...