11-1: Warranty Information
11 - Warranty Information
To avoid misunderstandings which might occur between machine owners and the
manufacturer, we are listing causes of component failure that specifically voids warranty
coverage. Such causes listed in this section shall constitute abuse or neglect.
BLOWER
• Failure to lubricate impellers daily with a HydraMaster-recommended lubricant, to
lubricate bearings, to maintain proper oil levels, or to use the correct oil grade and
viscosity as recommended in blower manual.
•
Failure to properly maintain blower safeguard systems such as waste tank filter screen,
vacuum safety relief valve and waste tank automatic shut-off system.
• Allowing foam to pass through blower.
HIGH PRESSURE WATER PUMP
• Failure to maintain proper oil level as recommended in pump manual.
• Failure to change oil in pump at recommended intervals.
• Failure to protect pump against freezing.
•
Failure to maintain pump protection shut-off system.
• Failure to use water softener in hard water areas.
• Use of improper chemicals.
RECOVERY TANK
•
Failure to properly maintain filtering devices in tank.
• Failure to clean tank as recommended by manufacturer.
• Failure to maintain vacuum safety release in tank.
• Use of improper chemicals.
CHEMICAL SYSTEM
• Use of improper chemical.
• Failure to use water softener in hard water area.
•
Operating machine without proper chemical filter screen.
• Failure to protect against freezing.
CONTROL PANEL
•
Failure to protect flowmeter and water pressure gauge against freezing.
Содержание Truckmount to Go TMTG 4000
Страница 2: ......
Страница 5: ...iii TMTG 4000 Owner s Manual ...
Страница 31: ...3 5 Cleaning Information ...
Страница 33: ...3 7 Cleaning Information 16 2 Evolution Flood Wand Item 000 163 058 Only 6 8 lbs ...
Страница 58: ...6 3 Water and Chemical System Figure 6 1 Flow Diagram View 1 of 3 000 179 038 Rev A ...
Страница 59: ...Water and Chemical System 6 4 Figure 6 2 Flow Diagram View 2 of 3 000 179 038 Rev A ...
Страница 124: ......