33: CTS 400 Flex Owner’s Guide
Daily
At the end of each day the internal components of the blower need to be lubricated. This
helps to prevent rust deposits and prolongs the life of the truckmount.
Lubricate the blower to prevent it from rusting internally by:
1. Allowing the unit to run for a few minutes with the vacuum hose disconnected in
order to remove moisture from the blower.
2. Capping off the inlet(s) to the recovery tank.
3.
Spraying a HydraMaster-recommended spray lubricant into the “BLOWER LUBE
PORT” for about 5 to 7 seconds while the unit is running.
4. Uncapping the inlet(s) and run the unit for another minute to allow the blower to cool
down.
Periodically
Change the oil in both ends of the blower after the initial 100 hours of use. Change the oil
each 500 hours of use thereafter.