![HydraMaster ChemDry CTS 400 Flex Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/hydramaster/chemdry-cts-400-flex/chemdry-cts-400-flex_owners-manual-and-maintenance-logs_2191694023.webp)
19: CTS 400 Flex Owner’s Guide
CARPET/UPHOLSTERY PROCEDURE
1.
Ensure the Flex tank(s) is full.
2. Connect all solution and vacuum hoses, and the APO hose (if equipped).
3. Drain the water box by opening the water box drain valve on the dash.
4.
Select “CARPET/UPH.” on the Solution Control switch (see
Figure 3).
5. Optional: Press the Auto Pump Out (APO) switch to the “ON” position.
The PUMP OUT system will not engage until the water level rises inside the
recovery tank.
6. Now proceed with the cleaning operation.
The machine will automatically shut down when it reaches its full capacity due
to the float switch located inside the recovery tank. When this occurs, turn the
Solution Control switch to “OFF” and empty the recovery tank. Then, turn the unit
back on and continue to clean.
CARPET/UPH.
Selection
Figure 3. Select “CARPET/UPH.” on Solution Control Switch