MCS 1000 Series
Error analysis / remedy
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 58 / 76
BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc
2012-06-15
Error status - "active high" and "active low"
In "active high" and "active low" operation, two errors can occur.
In case of error, proceed as follows:
1.
Check the operation voltage to the MCS.
2.
Check the measurement voltage (U
M1/2
) to the MCS.
3.
Perform a reset. Remove the connection cable of the MCS for 10 seconds.
Reconnect the connection cable to the MCS.
4.
If there is no change in the error status, contact HYDAC.
Observe the starting phase of ~ 70 seconds.
Error status 1 "active low"
The signal at the switching output is permanently free of voltage. The MCS has
detected an error.
0 V
0
U
t
U
M1/2
Operation voltage
ON
Measurement voltage U
M1/2
ON or OFF