FluidAqua Mobil - FAM 10
Clean the suction strainer.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 58 / 72
BEWA FAM10 3549460a en-us 2011-05-05.doc
2011-05-05
Clean the suction strainer.
NOTICE
Operation without a suction strainer
The pump will be destroyed
►
The FCU may not be operated without the suction strainer.
►
Clean the suction strainer regularly.
To protect the pump from coarse contamination particles and other foreign bodies, a
dirt trap with a strainer insert is fitted at the pump inlet.
Clean the suction strainer at regular intervals.
To disassemble/install the suction strainer, proceed as follows:
1. Unscrew the screw plug (1)
counterclockwise with an open-jaw
wrench.
2. Remove strainer insert (3) and
clean it.
3. Clean the strainer insert, flush it out
and then blow-flush it using
compressed air.
3. Check strainer insert (3) and sealing
ring (2) on the screw plug for
damage and replace if necessary.
4. Insert the strainer insert (3).
5. Manually screw in the screw plug
(1) clockwise.
Tighten the screw plug (1) with a
open-jaw wrench.
6. Check the suction strainer fitting for
leaks after commissioning.
1
2
3