FluidAqua Mobil - FAM 10
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 42 / 72
BEWA FAM10 3549460a en-us 2011-05-05.doc
2011-05-05
Error message
Cause
Remedy (also see
following detailed
description)
of the FCU.
Heater fault (only with
option heater)
Oil too hot due to
interruption of oil flow or
faulty thermostat.
Reset the safety
thermometer. Remove the
cover of the heater to do
so. Clean the suction
strainer, length of the
suction hose may need to
be shortened.
No parameterblock
Setup settings of the
TD200 deleted.
Reenter setup values.
(Please contact our
Technical Sales Office. For
contact information, see the
chapter "Foreword")
Electrical fuses
Automatic safety devices have been installed into the control cabinet for the security
of the operating voltage transformer.
Fuse
F1
The primary side of the transformer has 2A 400V
F2
The primary side of the transformer has 2A 400V
F3
The secondary side of the transformer has 3A 250V
F4
The secondary side of the transformer (control current circuit)
has 1A 250V
F5
The secondary side of the transformer (control current circuit)
has 1A 250V
F6
Contamination Sensor Display CSD (Optional)
F7
Contamination Sensor CS (Optional)