FluidAqua Mobil - FAM 10
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 51 / 72
BEWA FAM10 3549460a en-us 2011-05-05.doc
2011-05-05
Outlet (OUT) clogged
Step
Description
1. Fault:
"Outlet clogged"
Cause: Medium cannot flow out of the vacuum chamber (emptying
pump pressure limit = 5 bar)
2.
Check locking features in the return-flow line. Open if blocked.
3.
To reset the failure, press the RESET key
4.
Does the fault recur after
≈
4 minutes?
->a. Yes
-> proceed to Step 6.
5.
->b. No
-> proceed to Step 7.
6.
Check the pressure relief valve of the evacuation pump for proper
functioning.
7.
The failure is repaired.