Errors and troubleshooting
FCC-CM
en(us)
Page 50 / 60
BEWA FCC-CM 3648206 en-us 2016-07-08.docx
2016-07-08
Errors and troubleshooting
Error
Cause(s)
Remedy
Filter contami-
nated
Medium is heavily contaminated,
the filter element is worn.
Replace the filter ele-
ment.
The viscosity of the medium is
too high.
Warm the oil
Leaks at the
filter bowl
The drain plug at the filter bowl
or the tensioning clamp have not
been tightened properly.
Tighten the drain plug /
tensioning clamp on the
filter bowl.
Spare parts
The following spare parts are available for the unit
Article designation
Material p/no.
Filter bowl repair kit, comprising of:
- Filter bowl
- O-ring
- Oil discharge cap
- Tensioning clamp
NBR 349692
OLF repair kit, comprising of:
- O-rings
- Radial shaft seal
- Fastening screws
NBR 3054619
Filter element N5DM002
2 µm
349494
Filter element N5DM005
5 µm
3068101
Filter element N5DM020
20 µm
3023508
Replacement pump OLF-5/4 with seals
NBR 3052460
Replacement pump OLF -5/15 with seals
NBR 3052462
Filter element for breather filter 0007 L 010 P
10 µm
3064528
Suction strainer
300 µm
37575
Protective screen before Contamination Sen-
sor,
(1 pack = 10 items)
3536729
Replacement battery for the volume meter:
(Lithium CF ½ AA)
*
*) available on request