![Hydac FCC-CM 5/15 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/hydac/fcc-cm-5-15/fcc-cm-5-15_operating-and-maintenance-instructions-manual_2191270024.webp)
Setting up the unit
FCC-CM
en(us)
Page 24 / 60
BEWA FCC-CM 3648206 en-us 2016-07-08.docx
2016-07-08
Attaching/connecting the suction hose
NOTICE
High solid particle contamination in fluid
The filtration unit will be destroyed.
►
Never prime without a built-in suction screen.
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom of
the tank. The greatest contamination is found on the bottom of
the tank. All impurities and other particles are deposited on the
bottom of the tank.
Using the lance, put the suction hose into the appropriate reservoir without
tension or twist, and secure the suction hose against falling out or floating.
Attaching/connecting the pressure hose
Using the lance, put the pressure hose into the appropriate reservoir without
tension or twist, and secure the pressure hose against falling out or floating.
To prevent air from entering the medium, make sure that the
pressure hose with lance is always below the oil level in opera-
tion.